English
Language : 

CCK1-15A Datasheet, PDF (1/1 Pages) Littelfuse – Fork-Lift and Stud-Mounted Fuses
Special Purpose Fuses
Fork-Lift and Stud-Mounted Fuses
32 – 130 Volts DC  •  Fast Acting and Time-Delay
CNL/CNN Limiter Fuses
Specifications
Voltage Ratings:
Interrupting Rating:
Ampere Range:
Maximum Torque:
CNL: 32 Volts DC
CNN: 48 Volts DC, 75 Volts AC
2,500 amperes
10 – 800 amperes
90 Inch lbs.
Recommended Fuse Block
LFFB001
Ampere ratings
CNL fast-acting and CNN very fast acting fuses are rec­om­mend­ed for
CNL
35
80
150
250
350
use on battery operated lift trucks and other low voltage battery operated
40
100
175
275
400
equipment.
50
125
200
300
500
60
130
225
325
2.43"
CNN
10
80
175
300
500
35
90
200
325
600
40
100
225
350
700
3.18"
0.343"
50
125
250
400
800
60
150
275
Example part number (series & amperage): CNN 700
CBO/CCK/CCL Lift-Truck Fuses
CBO fast acting, and CCK and CCL dual-element time-delay fuses are rec-
ommended for fork lift trucks and other similar battery operated equipment.
Specifications
Part No.
CCK 1-15A
CCK 20-30A
CCK 35-60A
CCK 70-120A
CCK 140-200A
CCK 225-300A
CCL 30-60A
CCL 80-120A
A 2.43"
B
C
3.18"
CCK/CCL
A
2.810
3.060
3.629
4.129
4.362
4.612
3.060
3.38
B
2.204
2.454
3.454
3.579
3.829
2.454
2.70
1.625"
C
0.510
0.510
0.750
1.00
1.00
1.00
0.51
0.75
0.343"
0.812"
1.00"
CBO
Voltage Ratings: CBO: 32 Volts DC
CCK: 130 Volts DC (1-100A)
72 Volts DC (120-200A)
48 Volts DC (225-300A)
CCL: 125 Volts DC
Interrupting Rating: CBO, CCK & CCL: 10,000A
Ampere Range:
1 – 300 amperes
For operating characteristics contact factory
Ampere ratings
CBO
10
Fast Acting
12
15
20
CCK
1
Time-Delay
2
10
15
20
CCL
30
Time-Delay
35
25
50
80
30
60
100
35
70
125
40
75
150
25
60
120
30
70
140
35
75
150
40
80
160
50
100
175
40
60
100
50
80
120
Example part number (series & amperage): CCK 150
© 2005 Littelfuse • POWR-GARD™ Products Catalog
www.littelfuse.com
200
225
250
300