English
Language : 

ML9059E Datasheet, PDF (55/72 Pages) List of Unclassifed Manufacturers – 132-Channel LCD Driver with Built-in RAM for LCD Dot Matrix Displays
LAPIS Semiconductor
FEDL9059E-01
ML9059E
When Not Using the Internal Power Supply Immediately After Power-on
VDD-VSS Power supply ON when the pin RES = “L”
Power supply stabilization
Release reset state (RES Pin = “H”)
Initial settings state (default)
*1
*(a)
Start power save mode (compound command) *9
Function setting using command input (user settings)
LCD bias set
*2
ADC select
*3
Common output state select
*4
Line reversal/frame reversal drive
*5
select
Function setting using command input (user settings)
Setting voltage V1 adjustment internal resistor ratio *6
Electronic potentiometer
*7
Power save OFF
*9
Function setting using command input (user settings)
*(b)
Power control set
*8
Wait for more than 300 ms
*(c)
Initial setting state complete
*(a): Enter the power save state within 5ms after releasing the reset state.
*(b): Carry out power control set within 5ms after releasing the power save state.
The 5ms duration in *(a) and *(b) changes depending on the panel characteristics and the value of
the smoothing capacitor. We recommend verification of operation using an actual unit.
*(c): When trace resistance in COG mounting does not exist, wait for over 300 ms.
Since this value varies with trace resistance, V1, smoothing capacitors, or voltage multiplier
capacitors in COG mounting, confirm operation on an actual circuit board when using this LSI.
Notes:
*1:
*2:
*3:
*4:
*5:
*6:
*7:
*8:
*9:
Sections to be referred to
Functional description “Reset circuit”
Description of operation “LCD bias set”
Description of operation “ADC select”
Description of operation “Common output state select”
Description of operation “Line reversal/frame reversal drive select”
Functional description “Power supply circuit”, Description of operation “Voltage V1 adjustment
internal resistor ratio set”
Functional description “Power supply circuit”, Description of operation “Electronic
potentiometer”
Functional description “Power supply circuit”, Description of operation “Power control set”
The power save state can be either the sleep state or the standby state.
Description of operation “Power save (compound command)”
55/72