English
Language : 

ML7074-003 Datasheet, PDF (51/93 Pages) OKI electronic componets – VoIP CODEC
FEDL7074-003-01
ML7074-003
(16) CR15
B7
B6
B5
B4
B3
B2
B1
B0
R/W
CR15
TA
TA
TA
$
$
$
$
$
Mode in which
the value can be
I
I
I
R/W





changed
Initial value
0
0
0
0
0
0
0
0
B7 to B5: Registers for adjustment
Set to “010” at the beginning of the initialization mode.
(0, 1, 0): Fixed
B4 to B0: Reserved bits. Prohibited to change the initial settings.
(17) CR16
B7
B6
B5
B4
B3
B2
B1
B0
R/W
CR16
#
#
#
#
#
#
GPI1 GPI0
Mode in which
the value can be 







R/
changed
Initial value
0
0
0
0
0
0


B7 to B2: Reserved bits. Prohibited to change the initial settings.
B1: GPI1 level read out register
0: GPI1 level is “0”.
1: GPI1 level is “1”.
B0: GPI0 level read out register
0: GPI0 level is “0”.
1: GPI0 level is “1”.
Note:
GPI0 is used as the input of the dial pulse detector in the secondary functions. It is possible to read out GPI0
even when the dial pulse detector is operating.
51/93