English
Language : 

ZWQ80 Datasheet, PDF (1/2 Pages) DENSEI-LAMBDA – Quad output 80W ~ 130W
ZWQ-SERIES Quad output 80W ~ 130W
ZWQ80 (with -cover type)
Ⅵ Model name
ZWQ 80-5225/
Series Name
Output Voltage
ZWQ80
ZWQ130
1 year warranty
Output Wattage
Ⅵ Features
Option
blank: PCB type
L: L-shape metal plate type
A: with-cover type
ⅷ Built-in Active Filter , PFHC type
(EN61000-3-2)
ⅷ Compact, thin, PCB type Power Supply with quad output
ⅷ Wide output voltage range
V2.V3 output:×¢12V/×¢15V selectable
24V(30V) available by connecting in series
V4 output: 2V,3.3V,5V covered by 5V output (2.0-5.25V)
ⅷ Equipped with Remote ON/OFF control
ⅷ Wide input voltage range: 85-265VAC
ⅷ 1 year warranty
Ⅵ Specifications
1. Input voltage range 85~265VAC (47~63Hz), 120~370VDC universal input
2. Power factor
0.99 (typ) 100VAC at full load, 0.93(typ) 200VAC at full load
3. Output voltage range V1 : +5V = +5.0~+5.25V
V2 : +12V / +15V selectable
V3 : -12V / -15V selectable
4. Cooling
V4 : +5V = +2.0V~5.25V, +12V = +11.4V~12.6V, +24V = 22.8V~25.2V
Convection cooling
5. Operating ambient
temperature
Convection cooling -10°C~+40°C:100%, +60°C:50%
(Open frame type, Standard mounting)
6. Withstand voltage Input-output : 3kVAC (20mA) , Input-chassis : 2kVAC (20mA) , Output-chassis : 500VAC (100mA) for 1 min
7. Safety standard
ZWQ80 : Approved by UL1950 , CSA950(C-UL) , EN60950(TUV)
ZWQ130 : Conforms to UL1950, CSA950, EN60950, VDE0160
, VDE0160(TUV)
8. CE marking
9. EMI
10. PFHC
11. Functions
Conforms to low voltage directive
Meets EN55011-B, EN55022-B, FCC-B, VCCI-B
Meets EN61000-3-2
Over voltage protection, Over current protection, Remote on/off control
Ⅵ Product lineup
Model name
ZWQ80-5225
ZWQ80
ZWQ80-5222
ZWQ80-5224
ZWQ130-5225
ZWQ130
ZWQ130-5222
ZWQ130-5224
CH
Nominal
Min. output Max.
Max. peak Total max.
output voltage current (at peak) output current output current output power
UL CSA EN
V1
5V
0.9A(1.4A)
8.0A
V2
12(15)V
0A
2.0A
V3
–12(–15)V
0A
2.0A
V4
5V
0A
7.0A
V1
5V
0.9A(1.4A)
8.0A
V2
12(15)V
0A
2.0A
V3
–12(–15)V
0A
2.0A
V4
12V
0A
3.0A
V1
5V
0.9A(1.4A)
8.0A
V2
12(15)V
0A
2.0A
V3
–12(–15)V
0A
2.0A
V4
24V
0A
1.5A
V1
5V
1.5A(2.1A)
15A
10.0A
2.5A
2.5A
9.0A
10.0A
2.5A
2.5A
4.0A
10.0A
2.5A
2.5A
2.0A
19.0A
⅜⅜⅜
80W
⅜⅜⅜
(Peak 104W) ⅜ ⅜ ⅜
⅜⅜⅜
⅜⅜⅜
80W
⅜⅜⅜
(Peak 104W) ⅜ ⅜ ⅜
⅜⅜⅜
⅜⅜⅜
80W
⅜⅜⅜
(Peak 104W) ⅜ ⅜ ⅜
⅜⅜⅜
⅜⅜⅜
V2
12(15)V
0A
V3
–12(–15)V
0A
V4
5V
0A
4.0A
4.0A
10.0A
5.0A
5.0A
12.0A
130W
⅜⅜⅜
(Peak 170W) ⅜ ⅜ ⅜
⅜⅜⅜
V1
5V
1.5A(2.1A)
15.0A
V2
12(15)V
0A
4.0A
V3
–12(–15)V
0A
4.0A
V4
12V
0A
4.0A
V1
5V
1.5A(2.1A)
15.0A
V2
12(15)V
0A
4.0A
V3
–12(–15)V
0A
4.0A
V4
24V
0A
2.0A
19.0A
5.0A
5.0A
5.0A
19.0A
5.0A
5.0A
2.5A
⅜⅜⅜
130W
⅜⅜⅜
(Peak 170W) ⅜ ⅜ ⅜
⅜⅜⅜
⅜⅜⅜
130W
⅜⅜⅜
(Peak 170W) ⅜ ⅜ ⅜
⅜⅜⅜
⅜ : Safety standard approved
87