PF1000A Datasheet, PDF (1/2 Pages) DENSEI-LAMBDA – PFHC module 500W, 1000W | |||
|
PF-A-SERIES PFHC module 500W, 1000W
â
¥ Model name
PF 1000A-360
(Low Voltage Directive)
2 year warranty
Name of series Nominal output
power
Nominal output
voltage
â
¥ Features
â
· marking (Low Voltage Directive)
â
· PFHC module
Conforms to IEC 1000-3-2
High power factor: 0.95, high efficiency: 90%
Input: 85 ~ 265VAC
Output: 500, 1000W
â
· Wide baseplate temperature: â20 ~ +85°C
Conduction cooling
â
· Provided in-rush current limiting
â
· N+1 parallel redundant operation
â
· 2 year warranty
â
¥ Specifications
01. Input voltage range
02. Output
voltage/current
03. Efficiency (typ)
04. Power factor
05. In-rush current
06. Parallel operation
07. Cooling
08. Operating ambient
temperature
09. Withstand voltage
10. Safety standard
11. Functions
12. Recommended
noise filter
85 ~ 265VAC (50/60Hz) PFHC range: 85 ~ 255VAC (50/60Hz)
PF500A-360/85 ~ 265VAC input: DC360V 1.4A 504W
PF500A-360/170 ~ 265VAC input: DC360V 2.1A 756W
PF1000A-360/85 ~ 265VAC input: DC360V 2.8A 1008W
PF1000A-360/170 ~ 265VAC input: DC360V 4.2A 1512W
Output derating by input voltage/PF500A: 80% for 85VAC, 100% for 100 ~ 265VAC
Output derating by input voltage/PF1000A: 85% for 85VAC, 100% for 95 ~ 265VAC
90% (100VAC, full load), 94% (200VAC, full load)
0.95 (100VAC/200VAC at full load)
In-rush current limiting circuit: External limit resistor
N+1 redundant operation. Output current balancing (PC terminal)
Conduction cooling (Heatsink & airflow has to be chosen according to instruction manual)
Baseplate temperature: â20 ~ +85°C (output derating is different according to condition)
Ambient temperature: above â20°C
Input/output terminal to baseplate: 3.0kVAC for 1 min.
Approved by UL1950 , CSA950(C-UL) , and EN60950 (BSI)
Over voltage, Thermal protection, PFHC power on signal (ENA terminal), Inverter good signal (IOG terminal),
Auxiliary power supply for external signal (AUX terminal)
PN-F series
â
¥ Product lineup
Note 1
Model
Nominal voltage
range
Input voltage
range
PFHC operation
input voltage range
Input current (typ)
Nominal
output voltage
Max. output
current
Max. output
power
UL
CSA
EN
PF500A-360
100 ~ 240VAC
200 ~ 240VAC
85 ~ 265VAC
(47 ~ 63Hz)
170 ~ 265VAC
(47 ~ 63Hz)
85 ~ 255VAC
(47 ~ 63Hz)
170 ~ 255VAC
(47 ~ 63Hz)
5.6A
4.0A
PF1000A-360
100 ~ 240VAC
200 ~ 240VAC
85 ~ 265VAC
(47 ~ 63Hz)
170 ~ 265VAC
(47 ~ 63Hz)
85 ~ 225VAC
(47 ~ 63Hz)
170 ~ 255VAC
(47 ~ 63Hz)
11.2A
8.0A
â
· Request customer specification for further details of specifications, outline, characteristics, etc.
Read the instruction manual before usage.
â
· Contact us about delivery before ordering.
â
¥ Block diagram
360VDC
360VDC
360VDC
360VDC
1.4A
2.1A
2.8A
4.2A
504W
756W
1008W
1512W
â
â
â
â
â
â
â
â
â
â
â
â
â
: Safety standard approved
Note 1: Standard for input 100/200VAC and max. output power.
Note 1: The above specified value is on condition with external components
attached. Filtering capacitor and in-rush current limiting resistor are
required as external components.
Attach an external fuse at input line.