PBP-3201 Datasheet, PDF (1/2 Pages) DENSEI-LAMBDA – Equipment Designed to Conform EMI Regulations Such As VCCI,CISPR,FCC,VDE,etc    
PBP-SERIES
PBP-3201
PBP-3203
PBP-3204
Ⅵ Features
(1) For equipment designed to conform EMI
regulations such as VCCI, CISPR, FCC, VDE,
etc.
(2) Attenuates conductive emission from power
supply
(3) Leakage Current: 0.75mA max. (250V, 60Hz)
(4) Compact size
(5) Low price
Ⅵ Safety standard
UL1283,
CSA Std. C22. 2 No. 8
PBP-3202
Ⅵ Specifications
Item
Model
1 Rated voltage (AC, DC)
2 Rated current (AC, DC)
(Note)
3 Test voltage (terminal to case, AC 1 minute)
4 Isolation resistance (terminal to case, 500VDC)
5 Leakage current
125V, 60Hz
250V, 60Hz
6 DC resistance
7 Temperature rise
8 Operating temperature range
9 Weight (typ)
Ⅵ Circuit
PBP-3201-22
1A
0.5Ω max.
PBP-3202-22
PBP-3203-22
PBP-3204-22
250V
2A
3A
4A
1500V
100MΩ min
0.35mA max.
0.75mA max.
0.2Ω max.
0.1Ω max.
0.06Ω max.
30°C max.
–20 ~ +85°C
15g
(Note) : Value at Ta <=55°C. Refer to the derating curve shown below at Ta > 55°C.
Ⅵ Outline drawing
Ⅵ Derating
ⅷ Request customer specification for further details of specifications, outline, characteristics, etc.
Read the instruction manual before usage.
ⅷ Contact us about delivery before ordering.
Case: Plastic(UL94V-0)
Unit: mm
169