English
Language : 

PBF-1201 Datasheet, PDF (1/2 Pages) DENSEI-LAMBDA – Equipment Designed to Conform EMI Regulations Such As VCCI,CISPR,FCC,VDE,etc   
PBF-SERIES
PBF-1203-22
PBF-1201-22
Ⅵ Specifications
Item
Model
1 Rated voltage (AC, DC)
2 Rated current (AC, DC)
(Note)
3 Test voltage (terminal to case, AC 1 minute)
4 Isolation resistance (terminal to case, 500VDC)
5 Leakage current
125V, 60Hz
250V, 60Hz
6 DC resistance
7 Temperature rise
8 Operating temperature range
9 Weight
(typ)
Ⅵ Circuit
PBF-1206-22
PBF-1202-22
Ⅵ Features
(1) For equipment designed to conform EMI
regulations such as VCCI, CISPR, FCC, VDE,
etc.
(2) Attenuates conductive emission from power
supply
(3) Leakage current: 0.75mA max. (250V, 60Hz)
(4) Compact package
(5) Simple wiring and easy maintenance by
fast-on tab
(6) Low price
Ⅵ Safety standard
UL1283, CSA Std. C22. 2 No. 8
VDE0565 Teil. 3
( ) VDE0565 will transfer to EN133200
on and after July 23, 2003.
PBF-1201-22
1A
1.2Ω max.
PBF-1202-22
PBF-1203-22
PBF-1206-22
250V
2A
3A
6A
2500V
100MΩ min.
0.35mA max.
0.75mA max.
0.4Ω max.
0.2Ω max.
0.07Ω max.
30°C max.
–25 ~ +85°C
50g
(Note) : Value at Ta <= 55°C. Refer to the derating curve shown below at Ta > 55°C.
Ⅵ Derating
Ⅵ Outline drawings
ⅷ Request customer specification for further
details of specifications, outline, characteristics, etc.
Read the instruction manual before usage.
ⅷ Contact us about delivery before ordering.
Case: Plastic (PBT, UL94V-0)
(Unit: mm)
167