English
Language : 

MF1206 Datasheet, PDF (1/3 Pages) DENSEI-LAMBDA – Band wide:150kHz ~ 30MHz, 2 stage filter 
MF-SERIES
MF1206
MF1210
MF1216
Ⅵ Features
(1) Wide band: High attenuation.
Band wide: 150kHz ~ 30MHz, 2 stage filter
(2) Fast-on Terminals
(3) Compact, thin type package
Low profile metal case
10A type: 26mm
Ⅵ Safety standard
UL1283, CSA Std. C22. 2 No. 8 (C-UL)
VDE0565 Teil. 3
5653 EN133200
EN133200
(VDE0565 will expire on July 23, 2003.)
Ⅵ Specifications
Item
Model
1 Rated voltage (AC, DC)
2 Rated current (AC, DC)
(Note)
3 Test voltage (terminal to case, AC 1 minute)
4 Isolation resistance (terminal to case, 500VDC)
5 Leakage current
125V, 60Hz
250V, 60Hz
6 DC resistance
7 Temperature rise
8 Operating temperature
9 Operating humidity
10 Storage temperature
11 Storage humidity
12 Vibration
13 Safety standard
14 Weight
(typ)
Ⅵ Circuit
MF1206
MF1210
MF1216
6A
140mΩ max.
250V
10A
2500V (20mA) at 25°C, 70% RH
100MΩ min. at 25°C, 70% RH
0.5mA max.
1mA max.
50mΩ max.
40°C max.
–25 ~ +85°C
30% ~ 95% RH (No dewdrop)
–40 ~ +85°C
10% ~ 95% RH (No dewdrop)
16A
34mΩ max.
Sweep: 10 ~ 55 ~ 10 Hz (for one minute), Amplitude: 1,5 mm
X, Y and Z axes for 2 hours
Approved by UL1283, CSA C22.2 No. 8 (C-UL), VDE0565 Teil 3 and EN133200 (VDE).
190g
220g
310g
(Note) : Value at Ta <=35°C. Refer to the derating curve shown below at Ta > 35°C.
Ⅵ Derating
ⅷ Request customer specification for further details of specifications, outline, characteristics, etc.
Read the instruction manual before usage.
ⅷ Contact us about delivery before ordering.
156