English
Language : 

MAF1206 Datasheet, PDF (1/2 Pages) DENSEI-LAMBDA – Equipment Designed to Conform EMI Regulations Such As VCCI,CISPR,FCC,VDE,etc
MAF-SERIES
MAF-1215-33
MAF-1206-33
Ⅵ Specifications
Item
Model
1 Rated voltage (AC, DC)
2 Rated current (AC, DC)
(Note)
3 Test voltage (terminal to case, AC 1 minute)
4 Isolation resistance (terminal to case, 500VDC)
5 Leakage current
125V, 60Hz
250V, 60Hz
6 DC resistance
7 Temperature rise
8 Operating temperature range
9 Weight
(Typ)
Ⅵ Circuit
MAF-1220-33
MAF-1210-33
Ⅵ Features
(1) For equipment designed to conform EMI
regulations such as VCCI, CISPR, FCC, VDE,
etc.
(2) Attenuation effect against high voltage pulse
noise
(3) Attenuates conductive emission from power
supply
(4) Leakage current: 1mA max. (250V, 60Hz)
(5) High shielded effect
(6) Compact and light weight
Ⅵ Safety standard
UL1283, CSA Std. C22. 2 No. 8
VDE0565 Teil. 3
( ) VDE0565 will transfer to EN133200
on and after July 23, 2003.
MAF-1206-33
6A
0.10Ω max.
MAF-1210-33
MAF-1215-33
MAF-1220-33
250V
10A
15A
20A
2500V
100MΩ min.
0.5mA max.
1mA max.
0.05Ω max.
0.03Ω max.
0.02Ω max.
30°C max.
–25 ~ +85°C
290g
(Note) : Value at Ta <= 55°C. Refer to the derating curve shown below at Ta > 55°C.
Ⅵ Derating
Ⅵ Outline drawings
R : Breeder resistance
ⅷ Request customer specification for further details of specifications,
outline, characteristics, etc.
Read the instruction manual before usage.
ⅷ Contact us about delivery before ordering.
130
Case: Metal
(Unit: mm)