|
KYL-816 Datasheet, PDF (5/7 Pages) SHENZHEN KYL COMMUNICATION EQUIPMENT CO,LTD. – KYL-816AnalogWirelessAcquisition module UseManual | |||
|
◁ |
Shenzhen KYL Communication Equipment Co., Ltd
1ï¼Module address: from 000 to 255;
2ï¼Channel: total eight channels, each channel have different frequency;
3ï¼Transmission interval: it will be in effect only for the module under the point to
point transmission mode. The minimum interval will be different from the baud
rate of the module. When it set as â000â,the module work at the subordinate mode
and will receive or output data.
3ãUse of the software
1ï¼Connect the module with the PC and open the software of KYL-80X, then choose
the right port.
2ï¼Electrify, if connect success, the software will show â read successâ. Then âread
IDâ, read success, then can change the parameter.
Note:
1ï¼When set or read parameter, first need input the appointed ID that is the current
module address; also can know the current module address by âread IDâ, the
â write IDâ command can change the current module address.
2 ï¼ When set the channel, it canât exceed the max number channel for eight
channels. And the two module will be set the some channel, or they will not
communicate.
3ï¼Also can change the parameter by wireless. Connect the wireless data module
with the PC by UART port(not the UART port of the KYL-816),then can change
the parameter of the KYL-816.
4ï¼Under the point to point mode, many double equipment work at the same time,
different double equipment should be set different channel.
Fax: +86-0755-83408785 kyl03losia@gmail.com www.rf-data.com
|
▷ |