English
Language : 

KV7050R-P3 Datasheet, PDF (1/1 Pages) Kyocera Kinseki Corpotation – Voltage Controlled Crystal Oscillators (VCXO) Surface Mount Type
Voltage Controlled Crystal Oscillators (VCXO)
Surface Mount Type KV7050R-P3 Series
CMOS/ 3.3V/ 7.0×5.0mm
RoHS Compliant
Features
• High frequency to 800MHz
• LV-PECL output
• Miniature ceramic package
• Highly reliable with seam welding
• for WDM, Networking Applications
Table 1
Freq. Tol. Operating
Code
× 10-6
Temperature
Range (°C)
Note
Standard
G
±50
-40 to +85
specifications
With only cer-
tain frequencies
How to Order
KV7050R 622.080 P 3 G D 00
①
② ③④⑤⑥ ⑦
① Type (7.0×5.0mm SMD VCXO)
② Output Frequency
③ Output Type (LV-PECL)
④ Supply Voltage (3.3V)
⑤ Frequency Tolerance (See Table 1)
⑥ Symmetry/ INH Function
(45/ 55%, Disable)
⑦ Customer Special Model Suffix
(STD Specification is “00”)
  Packaging (Tape & Reel 1000 pcs./ reel)
Specifications
Item
Symbol
Output Frequency RangeNote1
fo
Frequency Tolerance
@VC=+1.65V
f_tol
Absolute Pull Range
Control Voltage
Storage Temperature Range
Operating Temperature Range
Max. Supply Voltage
Supply Voltage
Linearity
Current Consumption
Symmetry
Rise/ Fall Time
(20% to 80% Output Level)
Low Level Output VoltageNote2
High Level Output VoltageNote2
Output Load
Low Level Input Voltage
High Level Input Voltage
Input Resistance
Start-up Time
Disable Time
Enable Time
Phase Jitter
APR
VC
T_stg
T_use
—
VCC
—
ICC
SYM
tr/ tf
VOL
VOH
—
VIL
VIH
—
t_str
t_dis
t_ena
JPhase
Phase Noise
@622.08MHz
—
Conditions
Initial tolerance, Operating tem-
perature range, Rated power
supply voltage change, Aging (1
Op. Temp.: -40 to +85°C
year @25°C), Shock and vibration
VC=0V to +3.3V
50ohm @crossing point
50ohm
LV-PECL Output
@Minimum operating voltage to be 0 sec.
12kHz to 20MHz @622.08MHz
-  40 (@10Hz offset)
-  70 (@100Hz offset)
-  95 (@1kHz offset)
-105 (@10kHz offset)
-105 (@100kHz offset)
-125 (@1MHz offset)
-135 (@10MHz offset)
Note  : All electrical characteristics are defined at the maximum load and operating temperature range.
Note1: Please contact us for inquiry about operating temperature range, available frequencies and other conditions.
Note2: DC characteristic
Min.
10
Max.
800
Units
MHz
-50
+50
×10-6
±100
0
-55
-40
-0.5
+2.97
-10
—
45
—
+3.3
+125
+85
+4.2
+3.63
+10
100
55
—
0.4
—
VCC-1.620
VCC-1.025
—
50
—
30% VCC
70% VCC
—
150
—
—
10
—
200
—
2
—
1.0
×10-6
V
°C
°C
V
V
%
mA
%
ns
V
V
ohm
V
V
k ohm
ms
ns
ms
ps
dBc/ Hz
Dimensions
7.0
1.4
0.6
(Unit: mm)
Recommended Land Pattern (Unit: mm)
5.08
#4 #5 #6
#3 #2 #1
2.54 2.54
Plating: Ni+Au
Tolerance: ±0.2
Pad Connections
#1 VC
#2 INH
#3 Case GND
#4 Output
#5 Complementary Output
#6 VCC
Frequency Select Function
Pad2 Pad4/ Pad5 (Output)
Open
Active
"H" Level
Active
"L" Level High Z(Non-Oscillation)
2.54
1.6
Note: A capacitor of value 0.01µF between VCC