KC7050T-P2 Datasheet, PDF (1/1 Pages) Kyocera Kinseki Corpotation – SAW Clock Oscillators Surface Mount Type | |||
|
SAW Clock Oscillators Surface Mount Type
KC7050T-P2 Series
LV-PECL/ 2.5V/ 7.0Ã5.0mm
Pb Free
RoHS Compliant
Features
⢠Low voltage 2.5V
⢠Low jitter
⢠LV-PECL output
⢠Operation at fundamental
high frequency
⢠±50Ã10â6 Available
Table 1
Freq. Tol. Operating
Temperature
Code à 10â6 Range (°C)
Note
0
± 50
0 to +70
Standard
speciï¬cations
1 ±100 0 to +70 With only certain
A ±100 â5 to +85 frequencies
How to Order
KC7050T 312.500 P 2 0 E 00
á¶
ᶠá¶
á¶á¶á¶á¶
ᶠType (7.0Ã5.0mm SMD)
ᶠOutput Frequency
á¶
Output Type (PECL)
ᶠSupply Voltage (2.5V)
ᶠFrequency Tolerance (See Table 1)
ᶠS ymmetry/ Enable Function (45/ 55%, Stand-by)
ᶠC ustomer Special Model Sufï¬x
(STD Speciï¬cation is â00â)
ɹ Packaging (Tape & Reel 1000 pcs./ reel)
Speciï¬cations
Item
Output Frequency Range
Frequency Tolerance
Storage Temperature Range
Operating Temperature Range
Max. Supply Voltage
Supply Voltage
Current Consumption
(Standard Loaded)
Symmetry
Rise/ Fall Time
(20% to 80% Output Level Standard Loaded)
Low Level Output Voltage
High Level Output Voltage
Output Load (PECL)
Input Voltage Range
Low Level Input Voltage
High Level Input Voltage
Disable Time
Enable Time
Start-up Time
Deterministic Jitter (DJ)
1 Sigma Jitter
Peak to Peak Jitter
Symbol
fo
f_tol
T_stg
T_use
â
VCC
ICC
SYM
tr/ tf
VOL
VOH
RL
VIN
VIL
VIH
t_dis
t_ena
t_str
DJ
JSigma
JPK-PK
Conditions
Initial tolerance, Operating temperature range, Rated Op. Temp.: 0 to +70°C
power supply voltage change, Load change, Aging Op. Temp.: 0 to +70°C
(1 year @25°C), Shock and vibration
Op. Temp.: â5 to +85°C
Standard Speciï¬cations
2.5V
0 to +85°C/ Typ. 0.800V
â5 to 0°C/ Typ. 0.805V
0 to +85°C/ Typ. 1.550V
â5 to 0°C/ Typ. 1.495V
PECL 50Ω @Terminated VCCâ2V
@Minimum operating voltage to be 0 sec.
Measured with Wavecrest DTS-2079 VISI 6.3.1
Note: All electrical characteristics are defined at the maximum load and operating temperature range.
Please contact us for inquiry about operating temperature range, available frequencies and other conditions.
Min.
150
â50
â100
â100
â55
0
â0.5
2.375
Max.
700
+50
+100
+100
+125
+70
+5
2.625
â
90
45
55
â
600
VCCâ1.810 VCCâ1.405
VCCâ1.830 VCCâ1.305
VCCâ1.025 VCCâ0.740
VCCâ1.085 VCCâ0.880
49.5
50.5
0
VCC
â
30% VCC
70% VCC
â
â
200
â
10
â
10
0.2 typ.
2 typ.
20 typ.
Units
MHz
Ã10â6
°C
°C
V
V
mA
%
pS
V
ohm
V
V
V
nS
mS
mS
pS
pS
pS
Dimensions
7.00p0.2
3250A1ABA
KSS 5L
1.40
#4
#5
#6
#3
#2
#1
2.54 2.54
(Unit: mm) Recommended Land Pattern (Unit: mm)
Pad Connections
ᶠEnable/ Disable
ᶠNC
á¶
Case GND
ᶠOutput
ᶠComplementary Output
ᶠVCC
Plating: NiAu Enable/ Disable Function
Pad1 Pad4/ Pad5 (Output)
OPEN
Active
"H" Level
Active
"L" Level High Z (No-Oscillation)
Note: A capacitor of value 0.01MF and 10MF
between VCC and GND is recommended.
|