English
Language : 

KC5032A-CM Datasheet, PDF (1/1 Pages) Kyocera Kinseki Corpotation – CMOS/ 1.8V, 2.5V, 3.3V, 5.0V/ 5.0×3.2mm
Clock Oscillators Surface Mount Type
KC5032A-CM Series
CMOS/ 1.8V, 2.5V, 3.3V, 5.0V/ 5.0×3.2mm
RoHS Compliant
Features
• Wide operating voltage range 1.6 to 5.5V
• ±25×10-6 available
• Highly reliable with seam welding
• Miniature ceramic package
• CMOS output
Table 1
Freq. Tol. Operating
Code
× 10-6
Temperature
Range (°C)
Note
0 ± 50
Standard specifications
S ± 30 -10 to +70
U ± 25
With only certain
F
S
±100
± 50
-40 to +85
frequencies
How to Order
KC5032A 25.0000 C M 0 E 00
①
② ③④⑤⑥ ⑦
① Type (5.0×3.2mm SMD)
② Output Frequency
③ Output Type (CMOS)
④ Supply Voltage (1.8V, 2.5V, 3.3V, 5V Compatible)
⑤ Frequency Tolerance (See Table 1)
⑥ S ymmetry/ INH Function
(45/ 55%, Stand-by)
⑦ C ustomer Special Model Suffix
(STD Specification is “00”)
  P ackaging (Tape & Reel 1000 pcs./ reel)
Specifications
Item
Output Frequency Range
Frequency Tolerance
Storage Temperature Range
Operating Temperature Range
Max. Supply Voltage
Supply Voltage
Current Consumption
Stand-by Current
Symmetry
Rise/ Fall Time
(10% VCC to 90% VCC Maximum Loaded)
Low Level Output Voltage
High Level Output Voltage
Output Load
Input Voltage Range
Low Level Input Voltage
High Level Input Voltage
Disable Time
Enable Time
Start-up Time
Symbol
fo
f_tol
T_stg
T_use
—
VCC
ICC
I_std
SYM
tr/ tf
VOL
VOH
L_CMOS
VIN
VIL
VIH
t_dis
t_ena
t_str
Conditions
Min.
1.789
Initial tolerance, Operating tempera- Op. Temp.: -40 to +85°C
-100
ture range, Rated power supply volt- Op. Temp.: -10 to +70°C/ -40 to +85°C -50
age change, Load change, Aging (1 Op. Temp.: -10 to +70°C
-30
year @25°C), Shock and vibration Op. Temp.: -10 to +70°C
-25
-55
-40
-0.5
+1.6
1.6≤VCC≤2V
—
2<VCC≤2.8V
—
2.8<VCC≤3.63V
—
4.5≤VCC≤5.5V
—
—
@50% VCC
45
1.6≤VCC≤2V
—
2<VCC≤2.8V
—
2.8<VCC≤3.63V
—
4.5≤VCC≤5.5V
—
—
90% VCC
1.6≤VCC≤3.63V
—
4.5≤VCC≤5.5V
—
0
—
70% VCC
—
—
@Minimum operating voltage to be 0 sec.
—
1 Sigma Jitter
JSigma
—
Measured with Wavecrest DTS-2079 VISI 6.3.1
Peak to Peak Jitter
JPK-PK
—
Max.
50
+100
+50
+30
+25
+125
+85
+6.5
+5.5
5
6
7
9.5
10
55
8
7
6
5
10% VCC
—
15
50
VCC
30% VCC
—
150
5
10
8
80
Note: A ll electrical characteristics are defined at the maximum load and operating temperature range.
Please contact us for inquiry about operating temperature range, available frequencies and other conditions.
Units
MHz
×10-6
°C
°C
V
V
mA
μA
%
ns
V
V
pF
V
V
V
ns
ms
ms
ps
ps
Dimensions
5.0
0 .5
1.2
#3 #4
#2 #1
(Unit: mm) Recommended Land Pattern (Unit: mm)
2.5
Plating: Ni+Au
Tolerance: ±0.2
2.5
Pad Connections
#1 INH
#2 Case GND
#3 Output
#4 VCC
INH Function
Pad1
Pad3 (Output)
Open
Active
"H" Level
Active
"L" Level High Z (No-Oscillation)
1.6
Note: A capacitor of value 0.01µF between VCC
and GND is recommended.