KC3225A5000C30E00 Datasheet, PDF (1/1 Pages) Kyocera Kinseki Corpotation – Clock Oscillators Surface Mount Type KC3225A-C3 Series (K25-3C Series)
Clock Oscillators Surface Mount Type
KC3225A-C3 Series (K25-3C Series)
CMOS/ 3.3V/ 3.2×2.5mm
Pb Free
RoHS Compliant
Features
• Miniature ceramic package
• Highly reliable with seam welding
• CMOS output
• Supply voltage VCC=3.3V
• ±25×10-6 available
Table 1
Freq. Tol. Operating
Temperature
Code × 10-6 Range (°C)
Note
0 ± 50
Standard specifications
S ± 30 -10 to +70
U ± 25
With only certain
F
G
±100
± 50
-40 to +85
frequencies
How to Order
KC3225A 25.0000 C 3 0 E 00
①
② ③④⑤⑥⑦
① Type (3.2×2.5mm SMD)
② Output Frequency
③ Output Type (CMOS)
④ Supply Voltage (3.3V)
⑤ Frequency Tolerance (See Table 1)
⑥ S ymmetry/ Enable Function
(45/ 55%, Stand-by)
⑦ C ustomer Special Model Suffix
(STD Specification is “00”)
  P ackaging (Tape & Reel 2000 pcs./ reel)
Specifications
Item
Output Frequency Range
Frequency Tolerance
Storage Temperature Range
Operating Temperature Range
Max. Supply Voltage
Supply Voltage
Current Consumption
(Maximum Loaded)
Stand-by Current
Symmetry
Rise/ Fall Time
(10% VCC to 90% VCC Maximum Loaded)
Low Level Output Voltage
High Level Output Voltage
CMOS Load
Input Voltage Range
Low Level Input Voltage
High Level Input Voltage
Disable Time
Enable Time
Start-up Time
1 Sigma Jitter
Peak to Peak Jitter
Symbol
fo
f_tol
T_stg
T_use
—
VCC
ICC
I_std
SYM
tr/ tf
VOL
VOH
L_CMOS
VIN
VIL
VIH
t_dis
t_ena
t_str
JSigma
JPK-PK
Conditions
Initial tolerance, Operating tem- Op. Temp.: -40 to +85°C
perature range, Rated power supply Op. Temp.: -10 to +70°C/ -40 to +85°C
voltage change, Load change, Aging Op. Temp.: -10 to +70°C
(1 year @25°C), Shock and vibration Op. Temp.: -10 to +70°C
Standard Specifications
Extend (Option)
Freq. Tol.Code: 0, S, F
Freq. Tol.Code: U, G
1.5≤fo≤26MHz
26<fo≤50MHz
50<fo≤67.5MHz
67.5<fo≤95MHz
95<fo≤125MHz
@50% VCC
1.5≤fo≤67.5MHz
67.5<fo≤125MHz
IOL=4mA
IOH=-4mA
CMOS Output
@Minimum operation voltage to be 0 sec.
1.5≤fo≤60MHz
Measured with Wavecrest DTS-2079 60<fo≤125MHz
VISI 6.3.1
1.5≤fo≤60MHz
60<fo≤125MHz
Note: All electrical characteristics are defined at the maximum load and operating temperature range.
Please contact us for inquiry about operating temperature range, available frequencies and other conditions.
Min.
1.5
-100
-50
-30
-25
-55
-10
-40
-0.5
2.97
3.14
—
—
—
—
—
—
45
—
—
—
90% VCC
—
0
—
70% VCC
—
—
—
—
—
—
—
Max.
125
+100
+50
+30
+25
+125
+70
+85
+7
3.63
3.46
6
8
12
20
25
10
55
5
3
10% VCC
—
15
VCC
30% VCC
—
150
5
10
8
5
80
40
Units
MHz
×10-6
°C
°C
V
V
mA
µA
%
nS
V
V
pF
V
V
V
nS
mS
mS
pS
pS
pS
pS
Dimensions
3.2
0.90
ᶅ ᶆ
ᶄ ᶃ
1.00
(Unit: mm) Recommended Land Pattern (Unit: mm)

Plating: Ni Au
Tolerance: p0.1
Pad Connections
ᶃ Enable/ Disable
ᶄ Case GND
ᶅ Output
ᶆ VCC
Enable/ Disable Function
Pad1
Pad3(Output)
Open
Active
"H" Level
Active
"L" Level High Z (No-Oscillation)

.OTE!CAPACITOROFVALUEM&BETWEEN6##
AND'.$ISRECOMMENDED