KK135Z Datasheet, PDF (9/10 Pages) KODENSHI KOREA CORP. – Integrated circuit of temperature sensor | |||
|
◁ |
KK135Z
KK135Z
Thermo
couple
R3
Thermo electrical
coefficient
J
377 Ðhm 52,3 µV/оС
T
308 Ðhm 42,8 µV/оС
K
293 Ðhm 40,8 µV/оС
S
45,8 Ðhm 6,4 µV/оС
Adjustment: compensation of sensor and resistor
tolerances
1 Selection of 1N4568
2 Adjustment of voltage drop on element R3 by the
resistor R1 to obtain the value of thermoelectrical
coefficient, multiplied by the ambient temperature
(in K degrees).
3 Selection of 135Z and adjustment of R2 for
setting voltage drop on the element R3 according to
thermocouple type
J â 14,32 mV K â 11,17 mV
T â 11,79 mV S â 1,768 mV
Figure 22 â Circuit of cold junction compensation (compensation for ground thermocouple)
*Value of R3 nominal for this thermocouple type
KK135Z
Thermo-
couple
J
R3
1050
Ðhm
R4
365 Ðhm
Тhermoelectrical
coefficient
52,3 µV/оС
T
856 Ðhm 315 Ðhm
42,8 µV/оС
K
816 Ðhm 300 Ðhm
40,8 µV/оС
S
128 Ðhm 46,3 Ðhm 6,4 µV/оС
Adjustment: compensation of sensor and resistor tolerances
1 Adjustment by the resistor R1 for obtaining voltage drop on
the element R3, equal to thermoelectrical coefficient multiplied
by the ambient temperature (in K degrees)
2 Adjustment of the resistor R2 for obtaining some voltage
drop on the element R4 according to thermocouple type
J â 14,32 mV K â 11,17 mV
T â 11,79 mV S â 1,768 mV KK
Figure 23 â Circuit of cold junction compensation with unipolar supply
*Value of R3 and R4 nominals for this thermocouple type
9
|
▷ |