English
Language : 

KMEM001C Datasheet, PDF (1/2 Pages) KODENSHI KOREA CORP. – UV Sensor
UV Sensor
KME-M001C
DIMENSION
The KME-M001C UV Sensor combines a High Power
UV LED with LTV Sensor, Band pass filter.
FEATURES
Difficult for dust and debris to come onto element
Easy equipping
Detection of the Existence for a Fluorescent Material
APPLICATIONS
ATM
Vending Machine
etc
(Unit : mm)
MAXIMUM RATINGS
Parameter
Power Dissipation
Input
Forward Current
Peak Forward Current (1)
Reverse Current
Output
Supply Voltage
Output Current
Operating Temperature
Storage Temperature Range
ESD Withstand Voltage (Human Body Model)
Note 1. Pulse width ≤ 500usec ; Duty factor : 1%
Symbol
PD
IF
IFP
IR
VDD
IO
Topr
Tstg
VESD
Rating
60
25
80
60
6
10
-20 ~ 75
-25 ~ 85
±2.0
(Ta=25°C )
Unit
mW
mA
mA
mA
V
mA
°C
°C
kV
ELECTRO-OPTICAL CHARACTERISTICS
Parameter
Symbol
Conditions
Input
Forward Voltage
Peak Wavelength
VF
IF=20mA
λp
IF=20mA
Supply Voltage
VDD
-
Output
Dark Voltage
VD
Ee=0
Maximum Output Voltage
VOM
VDD=4.5V
Transmission
Forward Current
Low Level Output Voltage
L=4mm, VDD=5V,
IF
VTAR(2)= 4.5V,
Fluorescent Paper
L=4mm, VDD=5V,
VOL
ITAR(3), Non-
Fluorescent Paper
Response
Rise Time
tr
Time
Fall Time
tf
Note 2. VTAR = Target Voltage = 4.5V
Note 3. ITAR =IF(Forward Current) when VTAR
Note 4. Fluorescent Paper = HP Bright white inkjet paper (C5977B)
Min.
-
-
4.5
0
2
-
-
-
Typ.
3.5
375
5.0
4.49
-
-
160
150
1/2
(Ta=25°C )
Max. Unit
4.0 V
- nm
5.5 V
15 mV
V
20 mA
1
V
-
µs
-
µs