English
Language : 

SA05CT52A301N Datasheet, PDF (2/2 Pages) KOA Speer Electronics, Inc. – surge absorbers
SA
surge absorbers
environmental applications
Marking
First color code
Second color code
Third color code
Vs
DC Spark-Over Voltage
200V
240V
250V
300V
400V
500V
700V
First color
code
Red
Orange
Yellow
Green
Purple
Color Code
Second
color code
Third color code
Black
Yellow
Green
Black
DC Spark-Over Voltage
Tolerance
M ±20%: Plain
N ±30%: White
Performance Characteristics
Test Items
Spark-Over Voltage
Insulation Resistance
Electrostatic Capacitance
Resistance to Soldering Heat
Solderability
Terminal Strength
Rapid Change of
Temperature
Cold Resistance
Heat Resistance
Humidity Resistance
Surge Current Capacity
Test Methods
Spark-over voltage refers to voltage that starts discharging.
Discharge current shall be 0.5mA or under.
Measuring an insulatiuon resistance between terminals.
For measurement voltage, refer to a rating table.
1kHz, 6Vmax.
260°C±5°C, 10s±1s
235°C±5°C, 5s±0.5s
(Direct load); 5N,10s
(Bending test); 2.5N, 90°, 2 times
-40°C (30min.)/+125°C (30min.) 25 cycles
-40°C±3°C, 1000h
125°C±2°C, 1000h
40°C±2°C, 90%–95%RH, 1000h
8/20μs, 500A, 3 times
Surge Life
1500pF-10kV-0Ω, 200 times
Performance Requirements
Within regulated tolerance.
Within specified IR.
Within specified C.
Vs, IR, and C to be within specified values.
95% Coverage min.
No mechanical damage.
Vs, IR, and C to be within specified values.
Vs, IR, and C to be within specified values.
Vs, IR, and C to be within specified values.
Vs, IR, and C to be within specified values.
With no mechanical damage.
∆Vs/Vs≤30%
IR and C to be within specified values.
Specifications given herein may be changed at any time without prior notice. Please confirm technical specifications before you order and/or use.
12/16/09
KOA Speer Electronics, Inc. • 199 Bolivar Drive • Bradford, PA 16701 • USA • 814-362-5536 • Fax: 814-362-8883 • www.koaspeer.com
257