English
Language : 

2403-263-00092 Datasheet, PDF (21/25 Pages) Knowles Electronics – 8x15x1.5 HAC Receiver
Knowles Electronics
Dry Heat Operation Test
Parameter
Dry Heat
Operation
(Ref.
BSI BS EN-60068-2-
1
Signal used to be
agreed upon with
RIM )
Test Method and
Conditions
+70°C
rel. humidity not
controlled
Specification: 8x15x1.5 HAC Receiver
Order No. 2403 263 00092
Revision: A1.5.1 / 04.29.11
Duration
500h
Evaluation Standard
Measurements of acoustic
parameters shall be still
within specification.
Allowed deviations:
Sensitivity is allowed to be
within +/-3dB from initial
value;
The distortion shall not
increase by more than a
factor of 1.4 of the initial
value measured at a single
frequency bin.
E.g.: distortion at frequency
bin 400Hz which is initially
10% is allowed to be 14%
after the test.
4.5.3. Salt Mist Test
Parameter
Salt Mist
(Ref. IEC 60068-
2-52)
Test Method and
Conditions
The part must be
subjected to 2 hours
spray of 5% NaCl salt
mist, at 35°C then be
left at 40°C and 95%
RH for 22 hrs.
Duration
3 cycles
Evaluation Standard
Measurements of acoustic
parameters shall be still
within specification.
Allowed deviations:
Sensitivity is allowed to be
within +/-3dB from initial
value;
The distortion shall not
increase by more than a
factor of 1.4 of the initial
value measured at a single
frequency bin.
E.g.: distortion at frequency
bin 400Hz which is initially
10% is allowed to be 14%
after the test.
4.5.4. Shock Resistance Test (Free Fall Test) - protected product
Parameter
Mechanical shock
(Ref. IEC 60068-
Test Method and
Conditions
Drop in test box or test
adapter; Dropped onto
Duration
40 drops
Evaluation Standard
Measurements of acoustic
parameters shall be still
Knowles. 2011 All rights reserved.
page 21 of 25