J7523A Datasheet, PDF (7/8 Pages) Keysight Technologies – Cellular Passive Probe | |||
|
◁ |
07 | Keysight | Cellular Passive Probe - Data Sheet
Acquisition Card SFP/SFP+ Options
1000BASE-T Copper
ââ RJ-45
ââ Hot-pluggable
ââ Up to 100 m Cat 5 UTP
ââ Auto crossover detection
SONET OC-48/SDH STM-16 & 1000 BASE-LX
ââ LC connector
ââ Hot-pluggable
ââ 1310 laser
ââ Up to 2 km on 9/125 µm SMF
ââ Receiver sensitivity â8 dBm to â18 dBm
10 G BASE-LR & 1000 BASE-LX
ââ LC connector
ââ Hot-pluggable
ââ 1310 Laser
ââ Up to 10km on 9/125 μm SMF
ââ Receiver sensitivity -12.6 dBm to -19 bBm
Environmental
Specifications
Dimensions
Power
Cooling
Temperature operating
Temperature non-operating
Altitude
Humidity non-operating
Vibration non-operating
Safety
Electrostatic discharge (ESD)
Acoustic
Height
Width
Depth
Front clearance
Side clearance
Rear clearance
3.45 inches
17.14 inches
20 inches
2 inches
1 inch
3.6 inches
87.6 mm
435.3 mm
508 mm
51 mm
25 mm
92 mm
650 W AC or â48 V DC hot-swap, redundant power supplies
Hot-swap, redundant fans
5 °C to 35 °C (41 °F to 95 °F)
â40 °C to 70 °C (â40 °F to 158 °F)
0 to 1,800m (0 to 5,900 feet) @ 35 °C, 1,800 to 4,000m (5,900 to 13,100 feet) @ 30 °C
95%, non-condensing at temperatures of 23 °C (73 °F) to 40 °C (104 °F)
5 Hz @ 0.001 g2/Hz to 20 Hz @ 0.01g2/Hz (slope up)
20 Hz to 500 Hz @ 0.01 g2/Hz (flat)
Input acceleration is 2.2 g RMS
10 min per axis in all 3 axis on all samples
Random control limit tolerance in ±3 dB
UL 60950-1, 2nd Edition, 2011-12-19 (Information Technology Equipment - Safety - Part 1: General
Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information Technology Equipment -
Safety - Part 1: General Requirements)
Tested to ESD levels up to 15 kilovolts (kV) air discharge and up to 8 kV contact discharge without physi-
cal damage. Reliable operation up to 10 kV air discharge and 8 kV contact discharge.
Sound power: 65 dB(A) re 1 µW at 35 °C
|
▷ |