English
Language : 

W2360EP Datasheet, PDF (6/9 Pages) Keysight Technologies – Advanced Design System (ADS)
06 | Keysight | W2360EP/ET SIPro, W2359EP/ET PIPro - Data Sheet
PIPro
The following analyses can be performed
in PIPro:
DC IR drop analysis
–– Voltage delivered to each sink,
and failures based on user-defined
tolerances
–– Current flow through each via, and
failures based on user-defined
maximum values
–– 3D power dissipation visualization
–– 3D voltage distribution visualization
–– 3D current density visualization
Power plane resonance analysis
–– Analyze self-resonancesof the PCB
and inspect trouble areas that have
the highest field strength
–– Report self-resonant frequencies and
quality factors for the PDN
–– 3D field plots
Figure 3
Excessive DC current flowing
through individual vias, are
reported and highlighted in the
3D-geometry.
Figure 4
Visualization of DC voltage
distribution within the PDN.
Figure 5
Current density plot highlights
areas where resistance is high,
and quantifies the Amps per
mm2.
Figure 6
Power plane resonance analysis finds resonant frequencies of the board,
and shows the E-field to locate the problematic region of the board.