06 | Keysight | U2741A USB Modular Digital Multimeter - Data Sheet
Frequency specifications 1
Frequency accuracy
Function
Frequency
Range
20 Hz to 300 kHz
Accuracy
(% of reading + % of
range)
0.0200 + 0.003
Minimum input
frequency
1 Hz
Temperature
coefficient
(% of range)
0.005
Frequency Sensitivity for AC Voltage
Function
AC voltage
Range
100 mV 2
1V
10 V
100 V
250 V
Minimum sensitivity (RMS sine wave)
Frequency (Hz)
20 ~ 100k
20 mV
100 mV
1V
10 V
100 V
100k ~ 300k
20 mV
120 mV
1.2 V
20 V
120 V
Temperature specifications
Temperature specifications
Function
Temperature
Thermistor type
5 kΩ thermistor
Range
–80.0 °C to 150 °C
–112 °F to 302 °F
Accuracy
Temperature
coefficient
Probe accuracy + 0.2 °C 0.002 °C
NOTE: To ensure better measurement results and to guard against the change of environment or setup, always enable the Null offset.
Typical Reading Speed (in seconds) Characteristics
Test/Range
ACV
100 mV(20 Hz)
0.979
1V(20 Hz)
0.979
10V(20Hz)
0.978
100V(45 Hz)
0.979
300V(45 Hz)
0.979
Test/Range
ACI
10 mA
0.979
100 mA
0.979
1A
0.979
2A
0.979
Freq
1.190
1. Frequency measurement can only be done in auto range mode. Specifications are for 30 minutes warm-up time, using one second aperture.
Measuring method is using reciprocal counting technique with AC coupled input at AC voltage function. Gate time of 0.1 second or 1 second.
2. Only applicable for square wave measurement.