English
Language : 

N8802B Datasheet, PDF (6/8 Pages) Keysight Technologies – MIPI D-PHY Multilane Protocol
MIPI D-PHY Application Specifications and Characteristics
MIPI
MIPI sources
Data rate
Protocol type
Auto setup
Decoded fields
Triggering
(software-based)
Analog channels 1, 2, 3, or 4
Any waveform memories
The application relies on probing and trigger/measurement thresholds to properly condition the signal
for triggering and decode. Differential probing may be required.
Up to 2500 Mb/s
CSI-2 v1.00, DSI v1.01, DSI v1.02, DCS v1.02
Automatically configures scope settings for proper MIPI D-PHY decode and SW-based protocol triggering
including memory depth, edge triggering, holdoff, sample rate, and measurement thresholds
All including extended frame format
Short Packet
Long Packet
Low-Power Data Transmission
Errors
Any Error
Bad 166 CRC
Bad 86 ECC
Recommended Oscilloscopes
The D-PHY protocol decoder is compatible with Keysight Infiniium Series oscilloscopes with operating software revision 4.20 or
higher. For oscilloscopes with earlier revisions, free upgrade software is available here: www.keysight.com/find/scope-apps-sw.
Data rate
Up to 1 Gbps
Up to 1.5 Gbps
Up to 2.5 Gbps
Minimum bandwidth
4 GHz
6 GHz
12 GHz
Minimum channels
3
3
3
Recommended oscilloscopes
Infiniium 9000, S-Series, 90000 and Z-Series
Infiniium 90000 and Z-Series
Infiniium 90000 and Z-Series
Ordering Information
To purchase the D-PHY protocol decoder with a new or existing Infiniium Series oscilloscope, order the following options.
Software options
Application License type
Infiniium
Z-Series
Infiniium
S-Series
Infiniium
90000 Series
Infiniium
9000 Series
D-PHY
protocol
decoder
Fixed
Floating
Factory-installed
User-installed
Transportable
N8802A-1FP
N8802A-1FP
N8802A-1TP
N8802B-1FP
N8802B-1FP
N8802B-1TP
Option 019
N8802A-1NL
N8802A-1TP1,2
Option 019
N8802B-1NL
N8802B-1TP1,2
Server-based
N5435A-022
N5435A-022
N5435A-022
N5435A-022
1 Requires software 5.00 and above.
2 Software 4.30 or above requires Windows 7. N2753A Infiniium Windows XP to 7 OS upgrade kit (oscilloscope already has M890 motherboard). N2754A Infiniium Windows XP to 7 OS and
M890 motherboard upgrade kit (oscilloscope without M890 motherboard). Verify the M890 motherboard using the procedure found in the Windows 7 upgrade kit data sheet with the
publication number 5990-8569EN.
3 For full switch configuration, refer to www.keysight.com/find/switching or the brochure Automated Switching Solution for Oscilloscopes with the publication number 5991-2413EN.
Other hardware, probes and accessories
Model number
Description
1132A4
InfiniiMax 5-GHz differential probe amplifier
(quantity 4 recommended for 4 data lane decode)
E2669A
Differential probe connectivity kit (contains needed probe heads)
RTB
MIPI D-PHY reference termination board from UNH-IOL
https://www.iol.unh.edu/services/testing/mipi/fixtures.php
4 InfiniiMax I and II probes are suitable for D-PHY probing but not InfiniiMax III probes.
6
Quantity
3
1
1