Performance Specifications
N6783A-BAT
N6783A-MFG
DC Ratings:
Voltage
Current NOTE 1
Power
Low current measurement range
0-8V
– 2 to +3 A
24 W
150 mA
0-6V
– 2; 0 to +3 A
18 W
150 mA
Output Ripple and Noise (PARD):
(from 20 Hz – 20 MHz)
CV peak-to-peak
CV rms
8 mV
1.5 mV
8 mV
1.5 mV
Load Effect (Regulation):
(For any output load change, with a maximum load-lead drop of 0.5V/lead.
The load lead drop reduces the maximum available voltage at the load.)
Voltage
6 mV
Current
2 mA
6 mV
2 mA
Source Effect (Regulation):
Voltage
Current
2 mV
1 mA
2 mV
1 mA
Programming Accuracy:
(@ 23 °C ±5 °C after a 30 minute warm-up.
Applies from minimum to maximum programming range at any load.)
Voltage
0.1% + 10 mV
Positive Current
0.1% + 1.8 mA
Negative Current @ –2 A
0.2% + 1.8 mA
0.1% + 10 mV
0.1% + 1.8 mA
N/A
Measurement Accuracy:
(@ 23 °C ±5 °C.
Applies when measuring the default value of 1024 data points with a 20.48 μs time interval.)
Voltage
0.05% + 5 mV
Current high range
0.1% + 600 µA
Current low range
0.1% + 75 µA
0.05% + 5 mV
0.1% + 600 µA
0.1% + 75 µA
Load Transient Recovery
(Time to recover to within settling band for a load change from 0.15 A to 1.5 A and from 1.5 A to 0.15 A at 6 V output)
Voltage settling band NOTE 2
± 75 mV
± 75 mV
Time NOTE 2
< 45 µs
< 45 µs
1 Output current is derated 1% per °C above 40°C.
2 When relay Option 761 is installed, the settling band is ± 90 mV. The time is < 75 µs.