English
Language : 

Z2094B Datasheet, PDF (5/8 Pages) Keysight Technologies – Solar Array Simulator System
05 | Keysight | Solar Array Simulator System - Technical Overview
SAS System Characteristics
System controller
The core system includes a ruggedized industrial PC (IPC), rack
mounted in the SAS system controller. The customer may request
custom configurations. Basic features include:
–– Windows® operating system
–– Multicore processor, DVD RW multi drive, and 500G hard drive
–– 2 LAN ports, one for instruments, one for enterprise
connection
–– Monitor, mouse, and keyboard mounted on swing arm
–– Drawer style KBD and integrated display
Cooling
The SAS system has been designed to maximize the cooling
efficiency of the rack. Input air is routed from the front of the rack
to the top and rear to maximize cooling and minimize acoustic
noise.
Interconnect panel
The rack rear view below shows the Power Distribution Unit, LAN
I/O, and the main system switching chassis with output interface.
Input power
Keysight offers complete systems including custom designed
power distribution units (PDU) for your fully configured system.
These systems typically require three phase power due to the high
power demands of a large SAS system.
System software
The controller hosts the Solar Array Simulator System Control
tools (14360A).
The Solar Array Simulator System Control tools (14360A) are
a powerful addition that greatly simplify the programming and
control of multiple E4360A instruments. It consists of three
components: the Software Driver, the Configuration Wizard, and
the Server Control with Web GUI. For more information refer to
the URL: Keysight 14360A Solar Array Simulator System Control
Tools User Guide
Output modules
Currently, Keysight offers any combination of the following output
modules for configuration in the system as shown in the table
below.
Figure 3. Input AC power and output SAS power connectors. PDU configured as
three phase 208v at 60 Amps per phase or 360v at 60 Amps per phase.
Maximums For:
Power (Watts)
Open Circuit Voltage (Voc)
Volts
Voltage Point Voltage (Vmp)
Volts
Short Circuit Current (lsc)
Amps
Circuit Point Current (Imp)
Amps
E4361A
510
65
E4361A- E4361A- E4361A-
J01
J02
J03 E4362A
497.6 553.6 549.2 600
58
75
85
130
E4362A-
J01
594
117
E4362A- E4362A-
J02
J03
594
600
120
108
E4362A-
J04
596.6
170
E4362A- E4362A- E4362A-
J05
J06
J18
552.5 564.9
560
95
180
150
60
53.5
69.2
78.5
120
108
110
100
157
87.7
166.2
140
8.5
9.3
8
7
5
5.5
5.4
6
3.8
6.3
3.4
4
8.5
9.3
8
7
5
5.5
5.4
6
3.8
6.3
3.4
4
See E4360A data sheet for more details: Keysight E4360 Modular Solar Array Simulators Data Sheet.