English
Language : 

N1085A Datasheet, PDF (4/11 Pages) Keysight Technologies – PAM-4 Measurement Application
04 | Keysight | N1085A PAM-4 Measurement Application - Data Sheet
Debug and Verify Your Designs Quickly and Easily (Continued)
Select the desired PAM-4 test suite
The N1085A software application covers PAM-4 transmitter
measurements outlined in IEEE P802.3bs and four OIF-CEI-4.0
(56G) clauses. The tests are conveniently organized by clause.
Click on the desired test group, and the appropriate tests are
offered in Select Tests.
1. N1085A-1TP
–– Performs PAM-4 transmitter tests outlined in:
–– IEEE P802.3bs, Annex 120D, CDAUI-8 chip-to-chip
–– IEEE P802.3bs, Annex 120E, CDAUI-8 chip-to-module
Configure your measurements
Customize parameters that are specific to your setup, such as
data rate and attenuation. Use default values or enter your own
settings including number of waveforms taken; type of pattern;
and whether or not to remove the effects of test cables. Choose
Normal mode to test within limits or choose Debug mode to test
to your custom limits and adjust other test parameters.
2. N1085A-4TP
–– Performs PAM-4 transmitter tests outlined in:
–– OIF-CEI-56G-XSR-PAM4 (Extra Short Reach interface)
–– OIF-CEI-56G-VSR-PAM4 (Very Short Reach interface)
–– OIF-CEI-56G-MR-PAM4 (Medium Reach interface)
–– OIF-CEI-56G-LR-PAM4 (Long Reach interface)
3. N1085A-7TP
–– Provides the ability to control a switch, allowing users to use
a single channel to test multiple channels.