English
Language : 

E36104A Datasheet, PDF (4/8 Pages) Keysight Technologies – Programmable DC Power Supplies
04 | Keysight | E36100 Series Programmable DC Power Supplies - Data Sheet
Performance Specifications
Tolerance %
E36102A E36103A E36104A E36105A
DC output rating (0 to 40 °C)
Max. voltage
6V
20 V
35 V
60 V
Max. current
5A
2A
1A
0.6 A
Load regulation ± (% of output + offset)
Voltage
<0.01% +
2 mV
3 mV
6 mV
10 mV
Current
<0.02% +
250 µA
100 µA
50 µA
30 µA
Line regulation ± (% of output + offset)
Voltage
<0.01% +
1 mV
2 mV
4 mV
7 mV
Current
<0.02% +
250 µA
100 µA
50 µA
30 µA
Output ripple and noise (20 Hz to 20 MHz)
Voltage
RMS
350 µV
2 mV
4 mV
5 mV
Pk-Pk
10 mV
30 mV
60 mV
100 mV
Accuracy 12 months (23 °C ± 5 °C)
Programming accuracy ± (% of output + offset)
Voltage
0.05% +
3 mV
8 mV
12 mV
20 mV
Current
0.05% +
5 mA
1 mA
0.6 mA
0.4 mA
Readback accuracy ± (% of output + offset)
Voltage
0.05% +
3 mV
5 mV
8 mV
12 mV
Current
0.05% +
4 mA
1 mA
0.5 mA
0.3 mA
Small Current
0.25% +
40 µA
(0-20 mA)
40 µA
(0-8 mA)
40 µA
(0-4 mA)
40 µA
(0-3 mA)
Load transient recovery time
(Time to recover to within the settling band following a load change from 50% to 100% and from 100% to 50% of full load)
Voltage settling band
15 mV
50 mV
87.5 mV
150 mV
Time
<50 μs
<50 μs
<50 μs
<50 μs
E36106A
100 V
0.4 A
20 mV
20 µA
12 mV
20 µA
15 mV
150 mV
40 mV
0.3 mA
20 mV
0.2 mA
40 µA
(0-2 mA)
250 mV
<50 μs