English
Language : 

N6763A Datasheet, PDF (30/57 Pages) Keysight Technologies – DC Power Modules
Supplemental Characteristics (continued)
N6761A / N6762A N6763A / N6765A
N6764A / N6766A
Up-programming Settling Time with full resistive load: (Time from start of voltage change to 0.1% of full scale value)
Small voltage step
0 V to 10 V
0 V to 6 V/0 V to 10 V
0 V to 15 V/0 V to 29 V
Time
0.9 ms
0.8 ms/1.0 ms
0.8 ms/1.4 ms
Large voltage step
0 V to 50 V
0 V to 20 V
0 V to 60 V
Time
4 ms
3 ms
4.2 ms
Down-programming Time with no load: (time from start of voltage change to output voltage < 0.5 V)
Small voltage step
10 V to 0 V
6 V to 0 V/10 V to 0 V
15 V to 0 V/29 V to 0 V
Time
0.3 ms
0.55 ms/1.0 ms
0.6 ms/1.2 ms
Large voltage step
50 V to 0 V
20 V to 0 V
60 V to 0 V
Time
1.3 ms
1.8 ms
2.2 ms
Down-programming Settling Time with no load: (time from start of voltage change to 0.1% of full scale value)
Small voltage step
10 V to 0 V
6 V to 0 V/10 V to 0 V
15 V to 0 V/29 V to 0 V
Time
0.45 ms
0.8 ms/1.3 ms
0.8 ms/1.5 ms
Large voltage step
50 V to 0 V
20 V to 0 V
60 V to 0 V
Time
1.4 ms
2 ms
2.3 ms
Down-programming Time with Capacitive load: (time from start of voltage change to output voltage < 0.5 V)
Small voltage step
10 V to 0 V
6 V to 0 V/10 V to 0 V
15 V to 0 V/29 V to 0 V
Time
4.5 ms
2.2 ms/4.5 ms
2.3 ms/5.5 ms
Large voltage step
50 V to 0 V
20 V to 0 V
60 V to 0 V
Time
Capacitive load NOTE 4
23 ms
1000 µF
8.5 ms
4700 µF
10 ms
680 µF
Down-programming Capability:
Continuous power
7W
12.5 W
12.5 W
Peak current
3.8 A
15 A
6A
Over-voltage Protection:
Accuracy
0.25% + 0.25 V
0.25% + 0.15 V
0.25% + 0.3 V
With Option 761
0.25% + 0.25 V
0.25% + 0.45 V
0.25% + 0.6 V
With Option 760
-
0.25% + 0.45 V
0.25% + 0.6 V
Maximum setting
55 V
22 V
66 V
Response time
50 µs from occurrence of over-voltage condition to start of output shutdown
Output Ripple and Noise: (PARD)
CC rms:
2 mA
10 mA
4 mA
Common Mode Noise: (from 20 Hz – 20 MHz; from either output to chassis)
rms
500 µA
500 µA
750 µA
peak-to-peak
Remote Sense Capability:
Series and Parallel Operation:
< 2 mA
< 2 mA
< 3 mA
Outputs can maintain specifications with up to a 1-volt drop per load lead.
The load lead drop reduces the maximum available voltage at the load.
Identically rated outputs can be operated directly in parallel
or can be connected for straight series operation.
Minimum Output Turn-On Delay: (Time from when any Output On command is received until the output starts turning on)
Without relay option
32 ms NOTE 5
18 ms
18 ms
With relay Option 760
58 ms NOTE 5
44 ms
44 ms
1 If you are operating the unit below 255 µA in constant current mode, the output may become unregulated with the
following load conditions: The load resistance is <175 mΩ and the load inductance is >20 µH. If this occurs, an
UNRegulated flag will be generated and the output current may rise above the programmed value but will remain < 255 µA.
2 Correction On compensates for current flowing into the output capacitor during voltage transients
3 Stated values apply when the load resistance is at or close to zero. To determine the frequency for larger resistance valuess, refer to the
User’s Guide under “Measurement System Bandwidth”.
4 Modules can discharge the specified capacitive load from full scale to 0V at a rate of 4 times/second.
5 In Current priority mode, minimum delay is 23 ms without relays and 45 ms with relay Option 760.
N6731B-N6786A DC Power Modules
N6700B-N6705B Mainframes
30
Specifications Guide