English
Language : 

N1014A Datasheet, PDF (3/9 Pages) Keysight Technologies – Compliance and Debug Application
03 | Keysight N1014A SFF-8431 Compliance and Debug Application for 86100D DCA-X Oscilloscopes - Data Sheet
Transform Complexity into Simplicity
Satisfying the broad requirements of the SFF-8431 Specifications can be very complex. The data rate for each test group
varies based on which standard is being addressed in the product design. The tests between each SFF-8431 group vary, as do
the test limits. An example of one group of tests is below. The time for your test development team to read and interpret the
specification and then implement that understanding into test plans can take several months of effort.
Parameters - B
Crosstalk source rise/fall time (20 to 80%)
Crosstalk source amplitude (p-p differential)
Signal rise/fall time (20 to 80%)
Total jitter
Data dependent jitter
Data dependent pulse width shrinkage
Uncorrelated jitter
Transmitter Qsq
Parameters - B
Eye mask
Eye mask
Eye mask
Eye mask
Symbol
Conditions
Min
Tr, Tf
See 1, 2, D.6
See 1, 2, D.7
Tr, Tf
See D.6
34
TJ
See D.5
DDJ
DDPWS
See D.3
UJ
See 3, 2, D.4
Qsq
See 4
50
Symbol
Conditions
X1
Mask hit ratio of
X2
5x10-5
See D.2 and
Y1
Figure 19
Y2
Target Value
34
1000
Max
0.28
0.1
0.055
Units
ps
mV
ps
UI (p-p)
UI (p-p)
UI (p-p)
Value
0.12
0.33
95
350
Units
UI
UI
mV
mV
Development and characterization of advanced integrated
circuits is time-consuming and expensive. Designers utilize
test adapters to fully characterize their parts for use in their
own or their customer’s circuits. For more information about
these adapters, please visit http://shop.wilder-tech.com/
category_s/35.htm.
By pairing your test adapter or compliance board with the
86100D, 86108B and N1014A software, you will have the
simplest and most powerful solution available to optimize
your designs and offer the best products to your customers.
Phase trimmers and a pair of cables complement your setup
for the most consistent and accurate measurements.
Hosts and modules have unique interface connectors
and require compliance boards or test adapters to enable
connection to test equipment. Designers endeavor to
minimize the trace lengths on the compliance boards and
cable lengths.