20 | Keysight | U4164A Logic Analyzer Module - Data Sheet
Probe/Cables As Required to Connect to the Target System
Direct connect probes – Probes that connect directly between a connector or footprint on the
device under test and the front panel connector of the logic analyzer.
Probe type
Connectorless,
Soft Touch Pro
Connectorless,
Soft Touch Pro
Flying lead
Mictor
Model
number
U4206A
U4204A
U4203A
U4205A
Channels Maximum
data rate
34
4 Gb/s
34
4 Gb/s
34
1.5 Gb/s
34
600 Mb/s
Supported signal
types
Single-ended data,
Differential or
single-ended clock
Differential or
single-ended data,
Differential or
single-ended clock
Single-ended data,
Differential or
single-ended clock
Single-ended data,
Single-ended clock
Comments
Compatible with the U4164A
only. Requires one U4206A
per U4164A module. Use only
for U4164A quad-sample
state or quarter channel
timing modes. Refer to
U4206A user guide for
example that allows for mixed
modes of operation (e.g.
quad-sample is selectable by
pod pair)
Model number
U4208A
U4209A
Description
Probe/cable, 61-pin
ZIF, left wing, no
RC, 160-pin direct
connect to U4164A
Probe/cable, 61-pin
ZIF, right wing, no
RC, 160-pin direct
connect to U4164A
Maximum data rate
3.2 Gb/s typical
3.2 Gb/s typical
Comments
Compatible with the U4164A only. For
use with W4631A or W4636A DDR4 BGA
interposers that include RC network to
provide proper signal termination to the logic
analyzer. Uses quad-sample state mode to
capture DQ signals.
Compatible with the U4164A only. For
use with W4631A or W4636A DDR4 BGA
interposers. Includes RC network to provide
proper signal termination to the logic
analyzer. Uses quad-sample state mode to
capture DQ signals.