English
Language : 

E1401B Datasheet, PDF (2/8 Pages) Keysight Technologies – C-Size, High-Power VXI Mainframe, 13-Slot
General Characteristics
Airflow and Power Supply Serviceability
• Power input and cooling air intake is through the rear
• Power supply is serviceable through the rear panel
• Cooling air exhaust is through the sides and top
• Three air filters are mounted on the rear panel, accessible
without tools for cleaning
• Cableless power supply interconnect to the backplane
eliminates risk of miswiring
Power
The power supply generates backplane logic signals ACFAIL* and
SYSRESET* in full compliance with the VXI Specification, Revision 1.4.
Temp. Available Power
120–240 Vac(1)
Usable Power 120– Usable Power 100
240 Vac Input(2)
Vac Input(2)
25° C 1690 W
900 W
650 W
40° C 1690 W
800 W
650 W
55° C 1488 W
700 W
650 W
(1) Sum of voltages times the currents—not always usable due to thermal shutdown.
(2) Total output before thermal protection shutdown.
Product Specifications
VXI Characteristics
VXI device type:
Data transfer bus:
Size:
Slots:
Connectors:
Shared memory:
VXI buses:
Mainframe
All per VXIbus Specification, Rev. 1.4
C
13
P1/2
n/a
All per VXIbus Specification, Rev. 1.4
Remote Monitoring
A connector on the rear panel provides access to all the
power supply voltages, remote on/standby, ACFAIL,
SYSRESET, and +5VSTDBY.
Mechanical Specifications
mm
inches
Height without bottom feet:
310
12.2
Height with bottom feet:
323
12.7
Height with cable tray:
352 or 396
13.9 or 15.7
Width:
426
16.8
Depth without rear feet:
574
22.6
Depth with rear feet:
590
23.2
Weight:
21 kg / 46 lbs
Allow at least 100 mm (4 in) in front of the mainframe for terminal modules and cabling.
Allow 1 rack unit (EIA) = 1.75 inches for top ventilation.
Power Supply Protection
All outputs are protected from over-temperature, over-
voltage, over-current, short-to-ground, and short to other
supplies. Protection made is full shutdown. Recovery occurs
when standby or line is recycled.
Power Input
50-60 Hz input power:
Automatic voltage ranging, nominal range: 100-240 Vac ±10%
Nominal frequency range:
50-60 Hz ±10%
400 Hz input power:
Nominal voltage range:
100-120 Vac ±10%
Nominal frequency:
400 Hz ±10%
dc input power:
Input voltage range:
100 Vdc min. - 370 Vdc max.
Inrush current:
40 A max.
+5VSTDBY:
1 A max. (user-supplied; power taps
located on rear for input of standby
voltage and ground to backplane)
Note: Cannot be used on GFI circuit.