English
Language : 

N6765A Datasheet, PDF (14/57 Pages) Keysight Technologies – Modular Power System Family
Supplemental Characteristics (N6731B-N6746B)
N6731B/
N6741B
N6732B/
N6742B
N6733B/
N6743B
N6734B/
N6744B
N6735B/
N6745B
N6736B/
N6746B
Programming Ranges:
Voltage
15 mV – 5 .1 V
Current
60 mA – 10.2A/
60 mA – 20.4 A
15 mV – 8 .16 V
40 mA –6.375 A/
40 mA – 12.75 A
30 mV – 20.4 V
10 mA – 2.55 A/
10 mA – 5.1 A
40 mV – 35.7 V
5 mA – 1.53 A/
5 mA – 3.06 A
70 mV – 61.2 V
2.5 mA – 0.85 A/
2.5 m A – 1.7 A
100 mV – 102 V
1.5 mA – 0.51A/
1.5 mA – 1.02 A
Programming Resolution:
Voltage
3.5 mV
4 mV
7 mV
10 mV
18 mV
28 mV
Current
7 mA
4 mA
3 mA
2 mA
1 mA
0.5 mA
Measurement Resolution:
Voltage
3 mV
4 mV
10 mV
18 mV
30 mV
50 mV
Current
10 mA
7 mA
3 mA
2 mA
1 mA
0.5 mA
Programming Temperature Coefficient per °C:
Voltage
0.005% +0.1mV 0.005% + 0.1 mV
Current
0.005% + 1 mA 0.005% + 0.5 mA
0.005% + 0.2 mV
0.005% + 0.1 mA
0.005% + 0.5 mV
0.005% +0.05mA
0.005% + 0.5 mV
0.005% +0.02mA
0.005% + 1 mV
0.005% +0.02mA
Measurement Temperature Coefficient per °C:
Voltage
0.01% + 0.1mV 0.01% + 0.1 mV
Current
0.01% + 1 mA 0.01% + 0.5 mA
0.01% + 0.2 mV
0.01% + 0.1 mA
0.01% + 0.2 mV 0.01% + 0.5 mV 0.01% + 0.5 mV
0.01% + 0.05 mA 0.01% + 0.02 mA 0.01% + 0.02 mA
Measurement Small Signal Bandwidth: (– 3 db typical)
Voltage
25 kHz
25 kHz
Correction On NOTE 1
10 kHz
10 kHz
Current NOTE 2
25 kHz
25 kHz
Correction On NOTE 1
2 kHz
2 kHz
25 kHz
10 kHz
25 kHz
2 kHz
25 kHz
10 kHz
25 kHz
2 kHz
25 kHz
10 kHz
25 kHz
2 kHz
25 kHz
10 kHz
25 kHz
2 kHz
N6705 Mainframe Oscilloscope Measurement Accuracy: (@t 23 °C ±5 °C; accuracy of any individual point in the trace)
Voltage
0.1% + 25 mV 0.1% + 30 mV 0.1% + 45 mV 0.1% + 75 mV 0.1% + 130 mV 0.1% + 190 mV
Current
0.15% + 70mA 0.15% + 40 mA 0.15% + 20 mA 0.15% + 14 mA 0.15% + 12 mA 0.15% + 7 mA
Correction On NOTE 1 0.15% + 50 mA 0.15% + 30 mA 0.15% + 15 mA 0.15% + 10 mA 0.15% + 9 mA 0.15% + 5 mA
Up-programming and Down-programming Time with full resistive load:
(Time from 10% to 90% of total voltage excursion; for voltage setting from 0V to full scale and full scale to 0V)
20 ms
20 ms
20 ms
20 ms
20 ms
20 ms
Up-programming and Down-programming Settling Time with full resistive load:
(Time from start of voltage change to 0.1% of full-scale value; for voltage setting from 0V to full scale and full scale to 0V)
100 ms
100 ms
100 ms
100 ms
100 ms
100 ms
Over-voltage Protection:
Accuracy
0.25% + 50mV
With Option. 760 0.25%+600mV
With Option. 761 0.25%+600mV
0.25% + 50 mV
0.25% + 600 mV
0.25% + 600 mV
0.25% + 75 mV
0.25% + 350 mV
0.25% + 350 mV
0.25% + 100 mV
0.25% + 250 mV
0.25% + 250 mV
0.25% + 200 mV
0.25% + 300 mV
0.25% + 300 mV
0.25% + 250 mV
0.25% + 300 mV
0.25% + 300 mV
Maximum setting
7.5 V
10 V
22 V
38.5 V
66 V
110 V
Response time
50 µs from occurrence of over-voltage condition to start of output shutdown
N6731B-N6786A DC Power Modules
N6700B-N6705B Mainframes
14
Specifications Guide