• 1-Slot, C-size, register based
• Six 1x4 multiplexers
• Switch signals up to 1.3 GHz
• SMB male connectors for high performance
• Controls E1473A/E1475A RF expanders
• Tree-switching for high isolation, low VSWR
Agilent E1472A
Description
The Agilent E1472A 50 Ω RF Multiplexer is a C-size, 1-slot,
register-based VXI module. It is the ideal choice to route
test signals from your application to your test instruments
(i.e., oscilloscope and spectrum, network, distortion
analyzers, or other RF equipment). The E1472A is functionally
identical to the E1474A except for output impedance.
The RF multiplexer can be used as six multiplexers or
combined with others to form a larger tree-switched
multiplexer or a limited stubless matrix. You can easily and
inexpensively expand the E1472A via the E1473A 50Ω RF
multiplexer expander or via the E1475A 75Ω RF multiplexer
expander.
The E1472A can easily be programmed with SCPI commands
to scan multiple channels, where each channel is switched to
its common, one at a time. This module is arranged as six
independent banks of channels (Bank 0 through Bank 5),
each acting as a 1x4 one-wire multiplexer. Only one channel
in each bank can be connected to its common at any time.
The multiplexer relays are arranged in a tree-switched
configuration, providing high isolation and low VSWR. Each
channel consists of a nonlatching armature relay.
Refer to the Agilent Technologies Website for instrument
driver availability and downloading instructions, as well as for
recent product updates, if applicable.
PDFINFO H 5 6 1 1 - 0 1
Agilent Technologies