E1403C Datasheet, PDF (1/2 Pages) Keysight Technologies – A/B to C-Size P1 Active Adapter, 1-Slot
Agilent E1403C
A/B to C-Size P1 Active Adapter,
1-Slot
Data sheet
• Adapts A- or B-size VXI to C-size VXI
• Provides active extensions of P1 only
• Fits 1-slot or 2-slot (optional) modules
• Provides slave-only capability
Description
The Agilent Technologies E1403C 1- or 2-slot VXI carrier adapts A- or
B-size VXI modules for use in all C-size VXI mainframes. P1, which is
the only connector available, is a fully buffered extension. The E1403C
provides slave-only capability and cannot be used in Slot 0 or with bus
masters. The standard module is 1-slot wide; Option 010 is 2 slots wide,
however, it only connects to the backplane on the left-most slot. Any
number of adapters can be used in an Agilent VXI mainframe.
Many (but not all) VME cards can be adapted for the use in C-size VXI
mainframes using this module if they meet VXI mechanical and electrical
restrictions. However, this is not a supported configuration.
Refer to the Agilent Technologies Website for instrument driver avail-
ability and downloading instructions.
Cables
Cables are required for adapting B-size multiplexers in a C-size main-
frame. The B-size multiplexers require analog bus cables longer than
those shipped, and, therefore, longer ones must be ordered separately
to connect Multiplexer-to-Multiplexer and Multiplexer to the Agilent
E1411A/B C-size digital multimeter. These cables are necessary when
mounting a B-size multiplexer in a C-size adapter because of the differ-
ent spacing and positioning of the analog bus connectors on the B- and
C-size modules. The following cables are available:
1. Agilent E1411A/B DMM to B-size Multiplexer/E1403C Cable
part numbers:
Agilent E1326-61611 Analog Bus Cable, The E1326-61611 is the same
cable used with the B-size cardcage internal DMM configuration.
• Agilent E1411-61601 Multiplexer-to-DMM (FET Multiplexer only).
Order the Agilent E1411-80001 cable kit to get both the E1326-61611
long analog bus cable and the E1411-61601 digital bus cable together.
2. B-size Multiplexer/E1403C to B-size Multiplexer/E1403C Cable
part numbers:
• Agilent E1400-61605 Multiplexer-to-Multiplexer Cable. The E1400-
61605 is the same cable used to connect C-size Multiplexers together.
3. C-size Multiplexer to B-size Multiplexer/E1403C Cable
part numbers:
Agilent E1326-61611 Analog Bus Cable. The E1326-61611 is the same
cable used with the B-size cardcage internal DMM configuration.
General Specifications
VXI Characteristics
VXI device type
Size
Slots
Connectors
Shared memory
VXI buses
n/a
C
1 or 2
P1
n/a
n/a
Module Current
IPM
+5 V
0.1
+12 V
0
–12 V
0
+24 V
0
–24 V
0
–5.2 V
0
–2 V
0
Cooling/Slot
Watts/Slot
0.50
∆P mm H2O
0.02
Air Flow liter/s
0.10
Ordering Information
Description
A/B-to-C-Size, 1-slot Adapter
2-Slot Wide Adapter
IOM
0.01
0
0
0
0
0
0
Product No.
E1403C
E1403C 010