English
Language : 

ALS40 Datasheet, PDF (6/6 Pages) Kemet Corporation – IEC 60384-4 Long Life Grade 40/105/56
Cap
(µF)
150
150
220
330
470
680
1000
1500
1500
1500
1500
2200
2200
3300
3300
4700
6800
Case
Size
(mm)
36x52
36x62
36x82
36x105
51x82
51x105
77x75
66x105
90x67
90x75
77x105
90x98
77x146
77x146
90x146
77x220
90x220
ALS40 105°c
Article table als40 (105°C)
ESR (mW)
at 20°C
100Hz (max)
Impedance (mW)
at 20°C
10 KHz (max)
Ripple current(A) at
105°C
100 Hz 10 KHz
Type number
450 VDC (UR )
721
360
715
356
487
242
325
162
239
123
164
84
125
69
79
42
78
57
87
49
80
43
58
32
54
29
38
27
37
20
27
15
19
15
1.8
4.5
ALS4 - - 151DA450
1.9
4.8
ALS4 - - 151DB450
2.5
6.2
ALS4 - - 221DE450
3.2
7.9
ALS4 - - 331DF450
4.1
9.0
ALS4 - - 471KE450
5.3
11.3
ALS4 - - 681KF450
7.0
13.2
ALS4 - - 102ND450
8.9
17.1
ALS4 - - 152MF450
8.7
15.3
ALS4 - - 152QC450
9.3
16.7
ALS4 - - 152QD450
9.8
18.7
ALS4 - - 152NF450
12.5
22.5
ALS4 - - 222QH450
13.1
22.9
ALS4 - - 222NP450
14.6
22.0
ALS4 - - 332NP450
17.4
28.9
ALS4 - - 332QP450
21.9
32.0
ALS4 - - 472NT450
23.5
39.2
ALS4 - - 682QT450
**
Mounting Style 0=plain or 1=stud
Termination Style A,C,G,J,M or R
operational data
Reliability
Operational Lifetime
Please see separate BHC application
notes TD003 for calculating operational
life expectancy under customer specific
conditions.
The failure rate is derived from our periodic
test results. The failure rate (λR) is therefore
only given at test temperature for life tests.
An estimation is also given at 40°C. The
expected failure rate for this capacitor range
is based on our periodic test results for
capacitors with structural similarity. Failure
rate is frequently quoted in FIT (Failures In
Time) where 1 FIT = 1 x 10-9 failures per hour.
Failure rates include both catastrophic and
parametric failures
Ta
85°C
40°C
Failure rate per hour
220 FIT
10 FIT
Mechanical data
Mounting position
The capacitor can be mounted in any
position so long as the safety vent can
operate. It is possible for some electrolyte
to be expelled. As this is a conducting liquid,
suitable precautions should be instigated
by the system designer to avoid secondary
short circuits.
The capacitors are designed to be mounted
in free air and are not suitable for submersion
in liquid.
Vibration
10Hz to 55Hz at 0.75mm or 10g for 3x2hrs
duration. Except 220mm long cans 10Hz
to 55Hz at 0.35mm or 5g for 3x0.5hrs
duration.
Insulating resistance
> 100 Mohms at 100V d.c., across insulating
sleeve.
Voltage Proof
> 2500V d.c., across insulating sleeve.
Safety vent
A safety vent for over pressure is featured on
terminal deck. This is in the form of a rubber
plug designed to relieve build up of internal
pressure due to over stress or catastrophic
failure.
Statements of suitability for certain applications are based on our knowledge of typical operating conditions for such applications, but are not intended to constitute –
and we specifically disclaim – any warranty concerning suitability for a specific customer application or use. This Information is intended for use only by customers who
have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise
provided by us with reference to the use of our products is given gratis, and we assume no obligation or liability for the advice given or results obtained.
BHC and Evox Rifa Electrolytic Capacitors
81