T491C226K006AT Datasheet, PDF (14/23 Pages) Kemet Corporation – T491 Industrial Grade MnO2 Series | |||
|
◁ |
Tantalum Surface Mount Capacitors â Standard Tantalum
T491 Industrial Grade MnO2 Series
Reverse Voltage
Solid tantalum capacitors are polar devices and may be permanently damaged or destroyed if connected with the wrong polarity. The
positive terminal is identified on the capacitor body by a stripe plus in some cases a beveled edge. A small degree of transient reverse
voltage is permissible for short periods per the table. The capacitors should not be operated continuously in reverse mode, even within
these limits.
Temperature
25°C
85°C
125°C
Permissible Transient Reverse Voltage
15% of Rated Voltage
5% of Rated Voltage
1% of Rated Voltage
Table 2 â Land Dimensions/Courtyard
KEMET
Case
A
B
C
D
L
M
H
E1
Q
R2
S2
T
U
V
W
X1
Y1
Metric
Size
Code
EIA
3216â18
3528â21
6032â25
7343â31
6032-19
3528-15
7360-20
7360â38
7343-12
2012-12
3216â12
3528â12
6032â15
7343â20
7343â15
7343â43
7343â40
Density Level A:
Maximum (Most) Land
Protrusion (mm)
W
L
S
V1 V2
1.35 2.20 0.62 6.02 2.80
2.35 2.21 0.92 6.32 4.00
2.35 2.77 2.37 8.92 4.50
2.55 2.77 3.67 10.22 5.60
2.35 2.77 2.37 8.92 4.50
2.35 2.20 0.92 6.32 4.00
4.25 2.77 3.67 10.22 7.30
4.25 2.77 3.67 10.22 7.30
2.55 2.77 3.67 10.22 5.60
1.05 1.83 0.15 4.82 2.50
1.35 2.20 0.62 6.02 2.80
2.35 2.20 0.92 6.32 4.00
2.35 2.77 2.37 8.92 4.50
2.55 2.77 3.67 10.22 5.60
2.55 2.77 3.67 10.22 5.60
2.55 2.77 3.67 10.22 5.60
2.55 2.77 3.67 10.22 5.60
Density Level B:
Median (Nominal) Land
Protrusion (mm)
W
L
S
V1 V2
1.23 1.80 0.82 4.92 2.30
2.23 1.80 1.12 5.22 3.50
2.23 2.37 2.57 7.82 4.00
2.43 2.37 3.87 9.12 5.10
2.23 2.37 2.57 7.82 4.00
2.23 1.80 1.12 5.22 3.50
4.13 2.37 3.87 9.12 6.80
4.13 2.37 3.87 9.12 6.80
2.43 2.37 3.87 9.12 5.10
0.93 1.50 0.22 3.72 2.00
1.23 1.80 0.82 4.92 2.30
2.23 1.80 1.12 5.22 3.50
2.23 2.37 2.57 7.82 4.00
2.43 2.37 3.87 9.12 5.10
2.43 2.37 3.87 9.12 5.10
2.43 2.37 3.87 9.12 5.10
2.43 2.37 3.87 9.12 5.10
Density Level C:
Minimum (Least) Land
Protrusion (mm)
W
L
S
V1 V2
1.13 1.42 0.98 4.06 2.04
2.13 1.42 1.28 4.36 3.24
2.13 1.99 2.73 6.96 3.74
2.33 1.99 4.03 8.26 4.84
2.13 1.99 2.73 6.96 3.74
2.13 1.42 1.28 4.36 3.24
4.03 1.99 4.03 8.26 6.54
4.03 1.99 4.03 8.26 6.54
2.33 1.99 4.03 8.26 4.84
0.83 1.12 0.38 2.86 1.74
1.13 1.42 0.98 4.06 2.04
2.13 1.42 1.28 4.36 3.24
2.13 1.99 2.73 6.96 3.74
2.33 1.99 4.03 8.26 4.84
2.33 1.99 4.03 8.26 4.84
2.33 1.99 4.03 8.26 4.84
2.33 1.99 4.03 8.26 4.84
Density Level A: For low-density product applications. Recommended for wave solder applications and
provides a wider process window for reflow solder processes.
Density Level B: For products with a moderate level of component density. Provides a robust solder
attachment condition for reflow solder processes.
Density Level C: For high component desity product applications. Before adapting the minimum land
pattern variations the user should perform qualification testing based on the conditions outlined in IPC
standard 7351 (IPCâ7351).
¹ Height of these chips may create problems in wave soldering.
2 Land pattern geometry is too small for silkscreen outline.
© KEMET Electronics Corporation ⢠P.O. Box 5928 ⢠Greenville, SC 29606 (864) 963-6300 ⢠www.kemet.com
T2005_T491 ⢠2/3/2014 14
|
▷ |