English
Language : 

PME271 Datasheet, PDF (1/4 Pages) Kemet Corporation – EMI suppressor, classes X1, X2 and Y2, metallized paper
PME271
• EMI suppressor, classes X1, X2 and Y2, metallized paper
• The highest possible safety regarding
active and passive flammability.
• Self-extinguishing UL 94V-0 encapsulation
material.
• Excellent self-healing properties. Ensures
long life even when subjected to
frequent overvoltages.
• Good resistance to ionisation due to
impregnated dielectric.
• High dU/dt capability.
• Small dimensions.
• Safety approvals for worldwide use.
• The capacitors meet the most stringent
IEC humidity class, 56 days.
• The impregnated paper ensures
excellent stability giving outstanding
reliability properties, especially in
applications having continuous
operation.
TYPICAL APPLICATIONS
CONSTRUCTION
The capacitors are intended for use as
Multi-layer metallized paper. Encapsulated
interference suppressors in X1, X2 (across- and impregnated in self-extinguishing material
the-line) and Y2 (line-to-earth) applications. meeting the requirements of UL 94V-0.
TECHNICAL DATA
X2
X1
Y2
Y2
PME271M PME271E PME271Y PME271YA-E
Rated voltage VAC, 50/60Hz 275
300
250
300
Capacitance range µF
0.001–0.6 0.01–0.22 0.001–0.1 0.001–0.15
Temperature range °C
–40/+110 –40/+110 –40/+100 –40/+115
Climatic category IEC
40/110/56/B 40/110/56/B 40/100/56/B 40/115/56/B
Capacitance tolerance
± 10% for C > 0.1 µF, code K. ± 20% for C ≤ 0.1 µF, code M
Approvals
S, N, D, FI, VDE, SEV, IMQ, UL, CSA
Dissipation factor
≤ 1.3 % at 1 kHz
Insulation resistance
C ≤ 0.33 µF ≥ 12000 MΩ
C > 0.33 µF ≥ 4000 s
Measured at 500 VDC after 60 s, +23°C
In DC applications
Recommended voltage:
PME271 M, E ≤ 630 VDC
PME271 Y ≤ 1000 VDC
Resonance frequency
Tabulated self-resonance frequencies f0 refer to 5 mm
lead lengths.
Test voltage between
terminals
The 100% screening factory test is carried out at:
2150 VDC: PME271M and PME271E.
2700 VDC: PME271Y. The voltage level is selected to meet
the requirements in applicable equipment standards. All
electrical characteristics are checked after the test.
Vibration
IEC 68-2-6, Test Fc
ENVIRONMENTAL TEST DATA
3 directions at 2 hour each,
No visible damage, No open or short circuit
10 – 500 Hz at 0.75 mm or 98 m/s2
Bump
Solderability
IEC 68-2-29, Test Eb
IEC 68-2-20, Test Ta
4000 bumps at 390 m/s2
Solder globule method
No visible damage, No open or short circuit
Wetting time
for d ≤ 0.8 < 1 s
for d > 0.8 < 1.5 s
Active flammability EN 132400
Passive flammability IEC 384-14 (1993), EN 132400
Humidity
IEC 68-2-3, Test Ca +40°C and 90 – 95% R.H.
56 days
120