PHE850EA4100MA06R17 Datasheet, PDF (1/2 Pages) Kemet Corporation – New, small dimensions including low profile capacitors
PHE850
• EMI suppressor, class Y2, metallized polypropylene
•C
• New, small dimensions including low profile capacitors
RoHS
Compliant
typical applications
The capacitors are intended for use as
interference suppressors in Y2 (line-to-
earth) applications.
Not for use in series with the mains.
See www.kemet.com for more information.
Construction
Winding of metallized polypropylene.
Encapsulated in self-extinguishing material
meeting the requirements of UL 94V-0.
Technical data
L
B
H
0.5
p
∅d
b
l
Rated voltage
300 VAC, 50/60 Hz (ENEC,UL,cUL)
p
d std l max l b
Capacitance range µF
Temperature range °C
Climatic category IEC
Capacitance tolerance
Approvals
Dissipation factor tanδ
Insulation resistance
Resonance frequency
0.001–1.0
–55/+110
55/110/56/B
± 20% standard, other tolerances on request
ENEC, UL, cUL
Maximum values at +23 °C
C ≤ 0.1 µF 0.1 µF < C ≤ 1 µF
1 kHz 0.2%
0.15%
10 kHz 0.3%
0.4%
100 kHz 0.6%
–
C > 1 µF
0.1%
0.8%
–
C ≤ 0.33 µF: ≥ 30 000 MΩ
C > 0.33 µF: ≥ 10 000 s
Tabulated self-resonance frequencies f0 refer to 5 mm
lead lengths.
10.0 ± 0.4 0.6 17
15.0 ± 0.4 0.6/0.8* 17
22.5 ± 0.4 0.8
6
27.5 ± 0.4 0.8
6
37.5 ± 0.5 1.0
6
30 ±0.4
30 ±0.4
30 ±0.4
30 ±0.4
30 ±0.7
* Size 7.5 x 14.5 x 18.0 and bigger, d = 0.8
mm.
Tolerance in lead length
< 30 mm +0 mm
–1
30 mm
+5
–0
mm
Test voltage between
terminals
The 100% screening factory test is carried out at 5000
VDC and 2500 VAC. The voltage level is selected to meet
the requirements in applicable equipment standards. All
electrical characteristics are checked after the test.
In DC applications
Recommended voltage: ≤ 1250 VDC
Endurance
Environmental test data
EN/IEC 60384-14:2005
1.7 x UR VAC 50 Hz, once every hour
increased to 1000 VAC for 0.1 s,
1000 h at upper rated temperature
Vibration
IEC 60068-2-6, Test Fc 3 directions at 2 hour each,
No visible damage, No open or short circuit
10 – 55 Hz at 0.75 mm or 98 m/s2
Bump
IEC 60068-2-29, Test Eb 1000 bumps at 390 m/s2
No visible damage, No open or short circuit
Change of temperature IEC 60068–2–14
Test Na
Upper and lower rated
temperature 5 cycles
No visible damage
Active flammability EN/IEC 60384-14:2005
Passive flammability EN/IEC 60384-14:2005
Humidity
IEC 60068-2-3, Test Ca +40°C and 90 – 95% R.H.
56 days