English
Language : 

PHE840M Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – New, small dimensions including low profile capacitors
PHE840M
• EMI suppressor, class X2, metallized polypropylene
• 0.01 – 10.0 µF, 275/280 VAC, +105°C
• Small dimensions including low profile capacitors
RoHS
Compliant
typical applications
For worldwide use as electromagnetic
interference suppressor in all X2 and
across-the-line applications.
Not for use in series with the mains.
See www.kemet.com for more information.
Construction
Metallized polypropylene film encapsulated
with selfextinguishing epoxy resin in a box
of material recognized to UL 94 V–0.
Technical data
Rated voltage
Capacitance range
Capacitance tolerance
275 VAC 50/60 Hz (ENEC)
280 VAC 50/60 Hz (UL, cUL)
0.01 – 10.0 µF
± 20% standard, ± 10% option, ± 5% on request
Temperature range
Climatic category
–55 to +105°C
55/105/56/B
L
p
p
7.5 ± 0.4
10.0 ± 0.4
15.0 ± 0.4
22.5 ± 0.4
27.5 ± 0.4
37.5 ± 0.5
B
H
0.5
∅d
b
l
d
std l max l b
0.6 17 20 ±0.4
0.6 17 30 ±0.4
0.8 17 30 ±0.4
0.8 6 30 ±0.4
0.8 6 30 ±0.4
1.0 6 30 ±0.7
Approvals
Dissipation factor
ENEC, UL, cUL
Maximum values at +23°C
C ≤ 0.1 µF 0.1µF < C ≤ 1 µF
1 kHz 0.1%
0.1%
10 kHz 0.2%
0.4%
100 kHz 0.6%
–
C > 1 µF
0.1%
0.8%
–
Tolerance in lead length
< 30 mm
+0
–1
mm
30 mm
+5
–0
mm
Test voltage between
terminals
The 100% screening factory test is carried out at 2200
VDC. The voltage level is selected to meet the
requirements in applicable equipment standards. All
electrical characteristics are checked after the test.
Insulation resistance
C ≤ 0.33 µF: ≥ 30 000 MΩ
C > 0.33 µF: ≥ 10 000 s
In DC applications
Recommended voltage ≤ 760 VDC
Environmental test data
Endurance
EN/IEC 60384-14:2005
1.25 x UR VAC 50 Hz,
once every hour increased
to 1000 VAC for 0.1 s,
1000 h at upper rated temperature
Vibration
IEC 60068–2–6
Test Fc
3 directions at 2 hours each,
10–55 Hz at 0.75 mm or 98 m/s2
No visible damage
No open or short circuit
Bump
IEC 60068–2–29
Test Eb
1000 bumps at
390 m/s2
No visible damage
No open or short circuit
Change of temperature IEC 60068–2–14
Test Na
Upper and lower rated
temperature 5 cycles
No visible damage
Active flammability
EN/IEC 60384-14:2005
Passive flammability
Enclosure material of
UL94V–0 flammability class
Humidity
IEC 60068-2-3
Test Ca
+40°C and
90 – 95% R.H.
56 days