English
Language : 

PHE840EA5100MA01R17 Datasheet, PDF (1/2 Pages) Kemet Corporation – EMI suppressor, class X2, metallized polypropylene
PHE840E
• EMI suppressor, class X2, metallized polypropylene
• 0.01 – 10 µF, 300 VAC, +105°C
• New improved design: small dimensions including low profile capacitors
RoHS
Compliant
typical applications
Construction
For worldwide use as electromagnetic
interference suppressor in all X2 and
across-the-line applications.
Not for use in series with the mains.
See www.kemet.com for more information.
Metallized polypropylene winding,
encapsulated in self-extinguishing material
meeting the requirements of UL 94 V–0.
Technical data
Rated voltage
300 VAC 50/60 Hz
L
B
H
0.5
p
∅d
b
l
Capacitance range
Capacitance tolerance
Temperature range
Climatic category
0.01 – 10 µF
± 20% standard, ± 10% option
–55 to +105°C
55/105/56/B
P
d
std l max l b
10.0 ± 0.4
15.0 ± 0.4
22.5 ± 0.4
27.5 ± 0.4
37.5 ± 0.5
0.6 17 30
0.8 17 30
0.8 6 30
0.8 6 30
1.0 6 30
±0.4
±0.4
±0.4
±0.4
±0.7
Approvals
ENEC, UL, cUL
related to rated voltage and climatic category
Dissipation factor tanδ
Maximum values at +23°C
C ≤ 0.1 µF 0.1µF < C ≤ 1 µF
1 kHz 0.1%
0.1%
10 kHz 0.2%
0.4%
100 kHz 0.6%
–
C > 1 µF
0.1%
0.8%
–
Tolerance in lead length
<
30
mm
+0
–1
mm
30 mm
+5
–0
mm
Test voltage between
terminals
The 100% screening factory test is carried out at
2200 VDC. The voltage level is selected to meet the
requirements in applicable equipment standards. All
electrical characteristics are checked after the test.
Resonance frequency
Tabulated self-resonance frequencies f0 refer to
5 mm lead length.
Insulation resistance
C ≤ 0.33 µF: ≥ 30 000 MΩ
C > 0.33 µF: ≥ 10 000 ΩF
In DC applications
Recommended voltage ≤ 760 VDC
Environmental test data
Endurance
EN/IEC 60384-14:2005
1.25 x UR VAC 50 Hz, once every hour
increased to 1000 VAC for 0.1 s,
1000 h at upper rated temperature
Vibration
IEC 60068–2–6
Test Fc
3 directions at 2 hours each,
10–55 Hz at 0.75 mm or 98 m/s2
No visible damage
No open or short circuit
Bump
IEC 60068–2–29
Test Eb
1000 bumps at
390 m/s2
No visible damage
No open or short circuit
Change of temperature IEC 60068–2–14
Test Na
Upper and lower rated
temperature 5 cycles
No visible damage
Active flammability
EN/IEC 60384-14:2005
Passive flammability EN/IEC 60384-14:2005 Enclosure material of
UL1414
UL94V–0 flammability class
Humidity
IEC 60068-2-3
Test Ca
+40°C and
90 – 95% R.H.
56 days
49