ZG-1435-1B Datasheet, PDF (1/1 Pages) JMK Inc. – Operating Voltage = 125/250 Vac Operating Current = 1.0 Ampere
JMK, Inc
Operating Voltage = 125/250 Vac
Operating Current = 1.0 Ampere
Frequency of Operation = 60—400 Hz
Temperature Range (Storage) = -40 to 105 C
Temperature Range (Operating) = -40 to 65 C
Leakage current (Max) @ 125 V~, 60 Hz = 0.85 ma
Dielectric Withstand (L-Grd), (1 Minute) = 1500 Vac
Dielectric Withstand (L-L), (1 Minute) = 1500 Vdc
Order P/N: ZG-1435-1B for MIL-STD-461C
ZG-1435-1BD for MIL-STD-461D or E
The ZG-1435-1B filter has been designed for
systems operating under the requirements of
MIL-STD-461C. If MIL-STD-461D or E are speci-
fied then part number ZG-1435-1BD should be
specified. The difference is that the differential
capacitor is repositioned on the line side in order
to match the test configuration of 461D and E.
The filter case is environmentally sealed and is
designed to handle the shock and vibration of
wheeled vehicle installations.
The circuit uses feed through capacitors the
insertion loss is 60 db to 1.0 Ghz and beyond.