English
Language : 

ZF-1519-3 Datasheet, PDF (1/1 Pages) JMK Inc. – Operating Voltage= 115/240 Vac Operating Current Max= 3.0 amp
ZF-1519-3
Operating Voltage= 115/240 Vac
Operating Current Max= 3.0 amp
Operating Frequency= 50—400 Hz
Temperature Operating= —20 TO 50 deg. C
Die Withstand (Line to Case)= 1500V~ for 1 Min
Die Withstand (Line to Line)= 1500Vdc for 1min
Leakage Current = 1.2 ma @ 250 VAC, 60Hz
Discharge after 1.0 sec.= 34 V Max
Order Part Number ZF-1519-3
The ZF-1519-3 filter is configured to
work with systems that need to meet
MIL-STD-461D or E. The filter is de-
signed with feed through capacitors so
that the minimum common mode inser-
tion loss of 60 db can be maintained
out to the frequency of 1Ghz and be-
yond.
If more stringent environmental charac-
teristics are needed, this filter can be
adapted with minimal design changes
USA
EUR
JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115
email: info@jmkfilters.com
JMK Inc Glasgow G13 1DN Scotland UK PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884