English
Language : 

ZA-1536-10 Datasheet, PDF (1/1 Pages) JMK Inc. – The ZA-1536-10 filter has been designed to operate with the Mission power solutions “BADGER” power supply.
JMK, Inc
The ZA-1536-10 filter has been designed to operate
with the Mission power solutions “BADGER” power
supply. The combination will meet the requirements
of Mil-Std-461D or Mil-Std-461E.
Operating voltage (AC) = 115/120/200/220 V~
Operating Voltage (DC) = 100—375 Vdc
Operating current = 10 Amp
Operating frequency = DC—400 Hz
Operating temperature = (-55)—50C
Diel. withstanding (line - case) = 1500 Vac
Diel. withstanding (line - line) = 1500 Vdc
Leakage current = 0.4 ma Max. at 115 Vac, 400 Hz
Max residual voltage after 1 sec. = 34 Volts
Order P/N: ZA-1536-10
0.25 TAB TERM (3x)
ZA-1536-10
1
L
2
N
3
G
90
80
70
DM
60
50
40
30
20
CM
10
0
.01 .04 .1
.4 1
4 10
40 100
.02 .07 .2
.7 2
7 20
70
FREQUENCY (MEGAHERTZ)
6-32 INSERT (4PL)
3.030
2.430
3.88
0.29
0.25
2.00
0.25
0.60
0.25
1.745
2.24
0.90
0.25
2.000
2.50
1.75
1 23
6-32 INSERT (4PL)
USA
EUR
JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115
email: info@jmkfilters.com
JMK Inc Glasgow G13 1DN Scotland UK PH: 44-(0) 7785310729 FX: 44-(0) 141-589-1884