English
Language : 

MM-0637A-40C Datasheet, PDF (1/1 Pages) JMK Inc. – Operating Voltage = 48 Vdc Operating Current = 40,50,60 Amperes
MM-0637A-40C, -50C, -60C
Operating Voltage = 48 Vdc
Operating Current = 40,50,60 Amperes
Operating Temperature Range = -40 to 50 C
Dielectric Withstanding Voltage
Line to Line: 707 Vdc for 1 minute
Line to Case: 2250 Vdc for 1.0 min
40 Amps Order P/N:
MM-0637A-40C
50 Amps “
MM-0637A-50C
60 Amps “
MM-0637A-60C
Safety Agency Approvals
EN
R
60 950
C US
This filter features a very small mechanical package.
Even with this small size the common mode insertion
loss and differential loss are very good.
This filter has additionally been designed to operate with
severe unbalanced current loading. It can withstand up
to a 30% unbalance in line and return without degrading
the common mode insertion loss. This capability is very
useful when the filter is used in dual systems with
shared returns.
This filter package is ruggedly designed to operate in
automotive as well as telecommunication environments
LINE
LOAD
INSERTION LOSS vs. FREQUENCY
MM-0637A SERIES
70
60
50
40
DM
40
50
30
CM 60
20
10
0
.01 .04 .1
.4 1
4 10
40 100
.02 .07 .2
.7 2
7 20
70
FREQUENCY (MEGAHERTZ)
3.56
3.16
0.59
Ø0.610 (2x)
0.50
1.25
2.25
Ø0.220 (2x)
0.83 - 0.90
MAX
1.18
2.60
0.19
.25-20 UNC-2A (4 PL)
USA
EUR
JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115
email: info@jmkfilters.com
JMK Inc Glasgow G13 1DN Scotland UK PH: 44-(0) 7785310729 FX: 44-(0) 141 589 1884