LL-1355-6.3BHT Datasheet, PDF (1/1 Pages) JMK Inc. – LL-1355-6.3BHT
The LL-1355-6.3BHT filter has been designed to operate
with the VICOR Harmonic Attenuator Module (HAM) and
other associated power converters to meet Mil-Std-461C,
D, E & F.
It will be necessary to add transient protection across the
output of the filter to protect the HAM module.
It is also recommended that you use 5%, bipolar TVS
diodes. 2 x 130V and 1 x 150V diodes connected in
series.
Order P/N: LL-1355-6.3BHT
LL-1355-6.3BHT
Operating Voltage = ___________________ 85 to 250 V
Operating Current = ______________________6.3 Amp
Operating Frequency = __________________50/400 Hz
Operating Temperature, High = ______ See temp Curve
Operating Temperature = _______________ -40 to 70°C
Diel. Withstanding (line - case) = ___________1500 Vac
Diel. Withstanding (line - line) = ____________1500 Vdc
Leakage Current = _________ 2.5 ma at 220 Vac, 60 Hz
Max Residual Voltage after 1 sec = __________34 Volts
Calculated MTBF = ________2,142,107 Hrs @ 30°C GB