English
Language : 

KK-1222-25 Datasheet, PDF (1/1 Pages) JMK Inc. – Operating voltage = 18 - 36 VDC Operating current (max) = 25 amperes
This filter is intended to provide transient and
surge suppression for DC power systems. In
addition to transient and surge suppression
the filter also provides very good common
mode and differential mode insertion loss.
If the transient suppression network is
destroyed the filter has a switch which
will provided a contact closure for alerting a
surveillance system.
Operating voltage = 18 - 36 VDC
Operating current (max) = 25 amperes
Temperature range (storage) = -55 to 85 c
Temperature range (operating)
25 A = -40 to 55 c
23 A = " 60 c
21 A = " 64 c
19 A = " 68 c
17 A = " 73 c
Transient Clamping voltage = 42 - 52 V
Surge clamping voltage = 75 - 110 V
Discharge current (8/20 us) = 20,000 amp
Approvals: CSA class I, div 2 for hazardous
Locations (Pending)
KK-1222-25
USA
EUR
JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115
email: info@jmkfilters.com
JMK Inc Glasgow G13 1DN Scotland UK PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884