English
Language : 

HH-1590-12 Datasheet, PDF (1/1 Pages) JMK Inc. – Operating voltage = 100 Vdc Operating current = 12.0 Amp
JMK, Inc
HH-1590-12
Operating voltage = 100 Vdc
Operating current = 12.0 Amp
Operating temperature = (-40)—70C
Diel. withstanding (line - case) = 1500 Vdc (1.0 Minute)
Diel. withstanding (line - line) = 200 Vdc (1.0 Minute)
Order P/N: HH-1590-12
LINE
1
3
2
LOAD
4
5
HH-1545-12
AMBIENT TEMPERATURE VS OPERATING CURRENT
90
80
70
60
50
40
10 11 12 13 14 15 16
CURRENT (AMPS)
80
CM
70
60
DM
50
40
30
20
10
0
.01 .04 .1
.4 1
4 10
40 100
.02 .07 .2
.7 2
7 20
70
FREQUENCY (MEGAHERTZ)
This filter is a compact DC power
filter designed to operate in tele-
communications
equipment. The filter is non-
polarized and can operate over a
wide temperature range.
The filter is configuered to
function in the Mil-Std-461E or
the EN55022 environment.
This circuit board mount filter
uses very little space yet
provides a lot of attenuation to
meet todays emissions
requirements
2.75
0.22
2.30
0.60
0.25
2.00 1.50
0.50
0.125
0.19
0.08
0.025
USA
EUR
JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115
email: info@jmkfilters.com