English
Language : 

FF-2098B-3 Datasheet, PDF (1/1 Pages) JMK Inc. – 4,585,894 Hrs @ 30C GB
The FF-2098B-3 filter has been designed to operate with
the Vicor VIPAC and to allow the MIL COTS VIPAC
to meet the conducted emission requirements of
Mil-Std-461D, E or F.
The standard filter has a chassis mount enclosure but the
filter enclosure can be modified to add a connector input
or other terminals to suit your requirements.
The leads are Teflon but can be changed if the Teflon is
an issue.
The filter is lead free and RoHS.
Order P/N:
FF-2098B-3 (STD)
FF-2098B-3HT (High Temp)
Operating Voltage: ____________________ 85 to 250 V
Operating Current: ________________________ 3 Amp
Operating Frequency: ___________________50/400 Hz
Operating Temperature, High: _________________60°C
Operating Temperature, Low: _____________-20ºC, Std
: _____________ -40ºC, HT
Storage Temperature: ________________-40ºC—100ºC
Diel. Withstanding (line - case): ____________1500 Vac
Diel. Withstanding (line - line): _____________1500 Vdc
Leakage Current: ____________0.33 mA @ 220V, 60Hz
Max Residual Voltage after 1 sec: ___________ 45 Volts
Calculated MTBF: _________4,585,894 Hrs @ 30°C GB
FF-2098B-3
INSERTION LOSS vs. FREQUENCY
USA
EUR
JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115
email: info@jmkfilters.com
JMK Inc Glasgow G13 1DN Scotland UK PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884