English
Language : 

FF-2073-10 Datasheet, PDF (1/1 Pages) JMK Inc. – 15,959,598 Hrs @ 30C GB
The FF-2073-10 filter has been designed to operate with
the VICOR PFC MINI and to allow the MIL COTS PFC
MINI to meet the conducted emission requirements of
Mil-Std-461D, E or F.
The standard filter has a chassis mount enclosure but the
filter enclosure can be modified to add a connector input
or other terminals to suit your requirements.
The leads are Teflon but can be changed if the Teflon is
an issue.
The filter is lead free and RoHS.
Order P/N:
FF-2073-10 (STD)
FF-2073-10HT (High Temp)
Operating Voltage = ___________________ 85 to 250 V
Operating Current = ______________________ 10 Amp
Operating Frequency = __________________50/400 Hz
Operating Temperature, High = _____ -40ºC to 60°C, HT
Operating Temperature, Low = ____ -20ºC to 50°C, STD
Storage Temperature = ______________ -40ºC—100ºC
Diel. Withstanding (line - case) = ___________1500 Vac
Diel. Withstanding (line - line) = ____________1500 Vdc
Leakage Current = ____________2.5 mA @ 220V, 60Hz
Max Residual Voltage after 1 sec = __________34 Volts
Weight = _________________________________1.9 lb
Calculated MTBF = _______15,959,598 Hrs @ 30°C GB
FF-2073-10
INSERTION LOSS vs. FREQUENCY
USA
EUR
JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115
email: info@jmkfilters.com