FF-1503-18 Datasheet, PDF (1/1 Pages) JMK Inc. – Operating Voltage = 125 Vac Operating Current (Max) = 18 AMP A/C
Operating Voltage = _______________ 125 Vac
Operating Current (Max) = __________ 18 AMP A/C
Frequency = _____________________ 60 HZ
Temp range (Storage) = ____________ -40 to 125oC
Temp range (Oper.) @ 18.0 AMP= ___ -40 to 85oC *
Note: (cooling air may be required)
Dielectric Withstand volt (Ph—Case) = 1500 Vac
Dielectric Withstand volt (Ph—Ph) = __ 1500 Vdc
Leakage current @ 125 V~, 60 HZ = __ 0.3 MA max.
Discharge Voltage after 1.0 sec = ____ 43 V max.
Weight = _______________________ 1300 gr / 2.9 lb.
Order p/n: FF-1503-18
BRN
LINE
BLU
GRN/YEL
FF-1503-18
BRN
LOAD
BLU
OPERATING CURRENT VS AMBIENT TEMPERATURE
90
80
70
60
50
40
12.0 13.0 14.0 15.0 16.0 17.0 18.0
CURRENT (AMPS)
This filter is designed to operate
with forced air cooling.
The curve above shows the
operating temperature versus
current in “still air”.
With a 26 cfm fan supplying cooling
the operating temperature is
85o C.
With a 34 cfm fan supplying cooling
the operating temperature is
90o C.
6.0 - 7.0
0.23 - 0.30
BROWN
GRN / Y
1.25
BLUE
LINE
1.60 1.12
0.350
2.050
90
80
70
60
CM
50
40
30
DM
20
10
0
.01 .04 .1
.4 1
4 10
40 100
.02 .07 .2
.7 2
7 20 70
FREQUENCY (MEGAHERTZ)
5.00
6.0 - 7.0
0.23 - 0.30
BROWN
BLUE
LOAD
AWG #14
5 PLCS
2.25
2.75
0.39
4.220
10-32 INSERT
4 PLCS
USA
EUR
JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115
email: info@jmkfilters.com