FF-1319-13E
This filter has been designed to operate with the Vicor
"VI - HAMD / BAMD harmonic attenuator modules" to
meet EN55022, class B.
This is a special model with a modified form factor,
Raychem 44A0111 wire leads and a wide operating
range from –40C to +65C.
Order P/N: FF-1319-13E
LINE
BLUE
BROWN
GRN / YEL
LOAD
BLUE
BROWN
Operating Voltage = _________________DC to 270 Vac
Operating Current (Max) = ____________________ 13A
Operating Frequency = ___________________50/60 Hz
Temp. Range (Storage) = _______________-40 to 85°C
Temp. Range (Operating) (-13C) @ 13.0 A = -40 to 65ºC
INSERTION LOSS vs. FREQUENCY
Diel. Withstanding Voltage (Ph - Case) = ____ 1500 Vac
Diel. Withstanding Voltage (Ph - Ph) = ______1500 Vdc
Leakage Current @ 250 Vac, 60 HZ = _____2.7 mA Max
Discharge Voltage after 60 sec = ___________34 V Max
Calculated MTBF = __________________2,278,891 Hrs
Wire # Ref
001 Line (L1)
002
Load
003 Neut (L2)
004
Load
005
Earth